00197498-03_UM_SiplaceCA-Serie_EN - 第473页
User manual SIPLACE CA-Series 8 Station Extensions From software version SC.708.0 Edition 12/20 14 EN -DRAFT 8.2 Sensor for the Component Reject Bin 473 8.2 Sensor for the Component Reject Bin [001 16848-xx] Quer y compo…

8 Station Extensions User manual SIPLACE CA-Series
8.1 Nozzle Changers From software version SC.708.0 Edition 12/2014 EN -DRAFT
472
8.1.5 Component Reject Bin for the SIPLACE TwinHead
A component reject bin can be installed for the SIPLACE TwinHead. It is positioned next to the
finepitch Vision module.
8
Fig. 8.1 - 21 Component Reject Bin for the SIPLACE TwinHead

User manual SIPLACE CA-Series 8 Station Extensions
From software version SC.708.0 Edition 12/2014 EN -DRAFT 8.2 Sensor for the Component Reject Bin
473
8.2 Sensor for the Component Reject Bin
[00116848-xx] Query component reject bin X-Series/D3
The sensor for the component reject bin monitors whether the reject bin is seated correctly on its
mount.
– If the reject bin was not inserted correctly, the machine cannot be started.
– If the reject bin jumps out of its mount during the placement process, the machine is stopped
immediately to avoid a head crash.
Each reject bin can be monitored by a separate sensor.
8
PLEASE NOTE
When using a SIPLACE SpeedStar (C&P20 M) at a location without SWS, we recommend
that you install the optional sensor for the component reject bin.

8 Station Extensions User manual SIPLACE CA-Series
8.3 Component Camera for the TwinStar, FC Camera From software version SC.708.0 Edition 12/2014 EN -DRAFT
474
8.3 Component Camera for the TwinStar, FC Camera
8.3.1 Stationary P&P Component Camera (Type 25) 16 x 16, Digital (FC Camera)
Item no. 00119718-xx Stationary component camera 16x16 digital, type 25
8
Fig. 8.3 - 1 Stationary P&P component camera (type 25) 16 x 16, digital (FC camera)
(1) Camera housing with integral camera and camera amplifier
(2) Glass plate - illumination and lens levels below