12 4. To uch the Check Mark icon to save and exit Note: if suck back is need ed, touch the “Reverse” icon to setup motor reverse time 5. Press the foot switch to activate the “Timed” dispense cycle. Alternately, touch th…

11
5.2.4 To Change Pressure Unit Display
Note: The default pressure unit is PSI. To change pressure unit to BAR,
follow the instructions below.
1. Touch the Setup icon to enter the setup screen
2. Touch the “BAR” icon to change pressure unit to BAR
3. Touch the X icon to save and exit
5.2.5 Manual/Purge Dispense Cycle Setting:
1. Touch the Purge icon to select purge cycle.
The Purge icon will turn to green color.
2. Press and hold down the foot switch to activate the purge dispense cycle.
Alternately, touch and hold the Run icon on the display to activate the
purge dispense cycle.
5.2.6 Automatic Dispense Cycle Setting:
1. Touch the “Timed” mode icon to set the dispense time.
The icon will turn to green color.
2. Touch the “Dispense” icon to enter the setup screen
3. Touch the Up and Down arrows to set the desired dispense time

12
4. Touch the Check Mark icon to save and exit
Note: if suck back is needed, touch the “Reverse” icon to
setup motor reverse time
5. Press the foot switch to activate the “Timed” dispense cycle.
Alternately, touch the Run icon to activate the “Timed” dispense cycle.
Note: The unit has an “Interrupt” mode feature. In this mode, the
“Timed” dispense cycle can be disrupted if the foot switch is released and
resumed when the foot switch is depressed again.
6. Touch the “Interrupt” icon to activate “Interrupt” mode.
The icon will turn to green color.
5.2.7 Teach Mode Setting
In the teach mode, the dispense time will be accumulated as long as the
foot switch is depressed. This is helpful in determining the required
dispense time when dispense output is known.
1. Touch the “Teach” icon to enter the teach mode
2. Touch the “Time Reset” icon to set timer to zero
3. Press and hold down the foot switch, the dispense time will be
accumulated
4. Release the foot switch when the desired amount of fluid has dispensed
5. Touch the “Timed” icon to transfer the dispense time to “Timed” mode
6. The unit is now set to repeat this “Timed” cycle
5.2.8 To run in Continous Mode
The controller can be setup to repeat the run continuously.
1. Touch the Setup icon to enter the setup screen

13
2. Touch the “Run Method” icon
3. Enter the delay time (ex. 5000 ms)
4. Touch the “Countinous Run” icon
5. Touch the Check Mark icon to save and exit
The screen will look similarly to the screen below:
Note: If the controller is set to activate memory cell 1 and the delay time is
set at 5000 ms, the controller will activate memory 1 contiuously with 5000