00191494-01 - 第10页

Error Messages Short Reference SIPLACE 80 S-15/F3/G 03/99 Issue Software Version SR.010.x x 8 63 X-axis disabled CAUSE ● X-axis switched off at the axis contro ller switch. REMEDY ● X-axis should be switch ed on at the a…

100%1 / 124
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
7
52 BERO SZ2 not being actuated
CAUSE
Bad plugged connection of the screwdriver at the gantry board; motor control board
defective.
REMEDY
Check plugged connections; fit new motor control board, carry out calibration of the axes.
53 SZ2 only succeeded on second attempt
CAUSE
Stiffness in the gearwheel/pinion of the screwdriver; stiffness in the pusher movement; calibration
of the motor control board not optimal.
REMEDY
Maintain screwdriver; maintain segment; carry out calibration of the motor control board.
54 BERO SZ1 not being actuated
CAUSE
Bad plugged connection of the screwdriver at the gantry board; motor control board defective.
REMEDY
Check plugged connections; fit new motor control board, carry out calibration of the axes.
59 X-axis does not reach setpoint position
CAUSE
Mechanism jamming; toothed belt parted; drive motor with tacho defective; calibration of the axis
incorrect.
REMEDY
Check mechanism; fit new toothed belt; fit new motor with tacho; carry out axis calibration.
60 Y-axis does not reach setpoint position
CAUSE
Mechanism jamming; toothed belt parted; drive motor with tacho defective; calibration of the axis
incorrect.
REMEDY
Check mechanism; fit new toothed belt; fit new motor with tacho; carry out axis calibration.
61 Z-axis does not reach setpoint position
CAUSE
Cam disk in incorrect position at zero pulse; motor defective; Z-axis jamming.
REMEDY
Fit cam disk in correct rotational position; redetermine zero point correction; replace motor; carry
out axis calibration; fit spare placement head.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
8
63 X-axis disabled
CAUSE
X-axis switched off at the axis controller switch.
REMEDY
X-axis should be switched on at the axis controller switch.
64 Y-axis disabled
CAUSE
Y-axis switched off at the axis controller switch.
REMEDY
Y-axis should be switched on at the axis controller switch.
65 D1-axis disabled
CAUSE
DP1-axis switched off at the axis controller switch.
REMEDY
DP1-axis should be switched on at the axis controller switch.
66 D2-axis disabled
CAUSE
DP2-axis switched off at the axis controller switch.
REMEDY
DP2-axis should be switched on at the axis controller switch.
67 Star axis disabled
CAUSE
Star axis switched off at the axis controller switch.
REMEDY
Star axis should be switched on at the axis controller switch.
68 Z-axis disabled
CAUSE
Z-axis switched off at the axis controller switch.
REMEDY
Z-axis should be switched on at the axis controller switch.
75 Programmed position of Z-axis outside travel range
CAUSE
Machine data in the line computer erroneous; height reference run is not carried out on the PCB
conveyor.
REMEDY
Check the machine data in the line computer.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
9
79 Arm for turning station 1 has not swivelled out
CAUSE
Feed motor defective; proximity switch defective.
REMEDY
Replace feed motor; carry out axis calibration; fit new proximity switch.
80 Arm for turning station 2 has not swivelled out
CAUSE
Feed motor defective; proximity switch defective.
REMEDY
Replace feed motor; carry out axis calibration; fit new proximity switch.
94 DETERMINANT not correct during position recognition
CAUSE
The two fiducials of a circuit image are on one position; the three fiducials of a circuit image are in
a line.
REMEDY
Correct placement program in the line computer.
95 Fiducial missing in position recognition
CAUSE
Fiducial quality of a fiducial not adequate; PCB transport adjusted imprecisely; camera illumina-
tion defective; search field too small.
REMEDY
Clean fiducial; reteach fiducial (increase size of search field); check conveyor width; check stop-
per setting.
96 CORR_MOVE not correct during position recognition
CAUSE
The two fiducials of a circuit image are on one position.
REMEDY
Correct placement program in the line computer.
101 Track empty, no component during pick-up
CAUSE
On a single track at least three pick-up errors occurred immediately after one another; no compo-
nent in the pick-up position; set up for incorrect component (e.g. cubic instead of non-cubic).
feeder jamming; cover foil parted.
REMEDY
Refill components and reset track; check set-up.
get feeder working properly again.