97
1019 yk-axis: Target position not reached
CAUSE
Machine data not correct; mechanism is jamming;
drive motor, tachometer, incremental encoder, servo-amplifier defective; calibration of the axis
incorrect.
REMEDY
Check machine data; check the mechanism; check the axis calibration
or check the components; if necessary, replace
1020 Z-axis; GU1: Target position not reached
CAUSE
Machine data not correct; mechanism is jamming;
drive motor, tachometer, incremental encoder, servo-amplifier defective; calibration of the axis
incorrect. Cam is in incorrect position with respect to zero pulse
REMEDY
Check machine data; check the mechanism; check the axis calibration
or check the components; if necessary, replace, fit cam in correct rotational position; redetermine
zero point correction
1021 Z-axis; GU2: Target position not reached
CAUSE
Machine data not correct; mechanism is jamming;
drive motor, tachometer, incremental encoder, servo-amplifier defective; calibration of the axis
incorrect.
Cam is in incorrect position with respect to zero pulse
REMEDY
Check machine data; check the mechanism; check the axis calibration
or check the components; if necessary, replace, fit cam in correct rotational position; redetermine
zero point correction
1022 Z-axis; GU3: Target position not reached
CAUSE
Machine data not correct; mechanism is jamming;
drive motor, tachometer, incremental encoder, servo-amplifier defective; calibration of the axis
incorrect.
Cam is in incorrect position with respect to zero pulse
REMEDY
Check machine data; check the mechanism; check the axis calibration
or check the components; if necessary, replace, fit cam in correct rotational position; redetermine
zero point correction
1023 xk-axis: deactivated
CAUSE
Axis has been deactivated at the axis board (servo)
REMEDY
Switch on the axis at the axis card
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
98
1024 yk-axis: deactivated
CAUSE
Axis has been deactivated at the axis board (servo)
REMEDY
Switch on the axis at the axis card
1025 Z-axis; GU1: deactivated
CAUSE
Axis has been deactivated at the axis board (servo)
REMEDY
Switch on the axis at the axis card
1026 Z-axis; GU2: deactivated
CAUSE
Axis has been deactivated at the axis board (servo)
REMEDY
Switch on the axis at the axis card
1027 Z-axis; GU3: deactivated
CAUSE
Axis has been deactivated at the axis board (servo)
REMEDY
Switch on the axis at the axis card
1028 xk-axis: Position control does not work
CAUSE
The position control of the axis is not working properly; machine data are not correct
REMEDY
Switch off the machine (reset), check axis for stiffness of running; check the machine data
1029 yk-axis: Position control does not work
CAUSE
The position control of the axis is not working properly; machine data are not correct
REMEDY
Switch off the machine (reset), check axis for stiffness of running; check the machine data
1030 Z-axis; GU1: Position control does not work
CAUSE
The position control of the axis is not working properly; machine data are not correct
REMEDY
Switch off the machine (reset), check axis for stiffness of running; check the machine data
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
99
1031 Z-axis; GU2: Position control does not work
CAUSE
The position control of the axis is not working properly; machine data are not correct
REMEDY
Switch off the machine (reset), check axis for stiffness of running; check the machine data
1032 Z-axis; GU3: Position control does not work
CAUSE
The position control of the axis is not working properly; machine data are not correct
REMEDY
Switch off the machine (reset), check axis for stiffness of running; check the machine data
1033 X-axis: deactivated
CAUSE
Axis has been deactivated at the axis board (servo)
REMEDY
Switch on the axis at the axis card
1034 Y-axis: deactivated
CAUSE
Axis has been deactivated at the axis board (servo)
REMEDY
Switch on the axis at the axis card
1035 xk-axis: deactivated
CAUSE
Axis has been deactivated at the axis board (servo)
REMEDY
Switch on the axis at the axis card
1036 yk-axis: deactivated
CAUSE
Axis has been deactivated at the axis board (servo)
REMEDY
Switch on the axis at the axis card
1037 Z-axis; GU1: deactivated
CAUSE
Axis has been deactivated at the axis board (servo)
REMEDY
Switch on the axis at the axis card