00191494-01 - 第103页
Short Reference SIPLACE 80 S-15/F3/G Error Messages 03/99 Issue Software Version SR.010.x x 101 1044 Z-axis; GU1: Timeout CAUSE ● Axis does not reach position wit hin the specified time; axis se tting is not correct; mac…
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
100
1038 Z-axis; GU2: deactivated
CAUSE
● Axis has been deactivated at the axis board (servo)
REMEDY
● Switch on the axis at the axis card
1039 Z-axis; GU3: deactivated
CAUSE
● Axis has been deactivated at the axis board (servo)
REMEDY
● Switch on the axis at the axis card
1040 X-axis: Timeout
CAUSE
● Axis does not reach position within the specified time; axis setting is not correct; machine data not
correct; drive motor, tachometer, incremental encoder, servo-amplifier defective;
mechanism is jamming
REMEDY
● Check the axis calibration; check machine data; or check the components; if necessary, replace;
check the mechanism;
1041 Y-axis: Timeout
CAUSE
● Axis does not reach position within the specified time; axis setting is not correct; machine data not
correct; drive motor, tachometer, incremental encoder, servo-amplifier defective;
mechanism is jamming
REMEDY
● Check the axis calibration; check machine data; or check the components; if necessary, replace;
check the mechanism;
1042 xk-axis: Timeout
CAUSE
● Axis does not reach position within the specified time; axis setting is not correct; machine data not
correct; drive motor, tachometer, incremental encoder, servo-amplifier defective;
mechanism is jamming
REMEDY
● Check the axis calibration; check machine data; or check the components; if necessary, replace;
check the mechanism;
1043 yk-axis: Timeout
CAUSE
● Axis does not reach position within the specified time; axis setting is not correct; machine data not
correct; drive motor, tachometer, incremental encoder, servo-amplifier defective;
mechanism is jamming
REMEDY
● Check the axis calibration; check machine data; or check the components; if necessary, replace;
check the mechanism;
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
101
1044 Z-axis; GU1: Timeout
CAUSE
● Axis does not reach position within the specified time; axis setting is not correct; machine data not
correct; drive motor, tachometer, incremental encoder, servo-amplifier defective;
mechanism is jamming.
REMEDY
● Check the axis calibration; check machine data; or check the components; if necessary, replace;
check the mechanism;
1045 Z-axis; GU2: Timeout
CAUSE
● Axis does not reach position within the specified time; axis setting is not correct; machine data not
correct; drive motor, tachometer, incremental encoder, servo-amplifier defective;
mechanism is jamming.
REMEDY
● Check the axis calibration; check machine data; or check the components; if necessary, replace;
check the mechanism;
1046 Z-axis; GU3: Timeout
CAUSE
● Axis does not reach position within the specified time; axis setting is not correct; machine data not
correct; drive motor, tachometer, incremental encoder, servo-amplifier defective;
mechanism is jamming.
REMEDY
● Check the axis calibration; check machine data; or check the components; if necessary, replace;
check the mechanism;
1047 X-axis: Target position outside of travel range
CAUSE
● The measurement of the head references does not match the travel range of the X-axis.
REMEDY
● Remeasure the head references; remeasure the minimum/maximum positions of the axis.
1048 Y-axis: Target position outside of travel range
CAUSE
● The measurement of the head references does not match the travel range of the Y-axis.
REMEDY
● Remeasure the head references; remeasure the minimum/maximum positions of the axis.
1049 xk-axis: Target position outside of travel range
CAUSE
● The measurement of the head references does not match the travel range of the xk-axis
REMEDY
● Remeasure the head references; remeasure the minimum/maximum positions of the axis
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
102
1050 yk-axis: Target position outside of travel range
CAUSE
● The measurement of the head references does not match the travel range of the yk-axis
REMEDY
● Remeasure the head references; remeasure the minimum/maximum positions of the yk-axis
1051 Z-axis; GU1: Target position outside of travel range
CAUSE
● The minimum/maximum positions of the Z1-axis are not correct; height of the head is not correct
REMEDY
● Adjust the minimum/maximum positions and zero point correction correctly; specify the head
height correctly.
1052 Z-axis; GU2: Target position outside of travel range
CAUSE
● The minimum/maximum positions of the Z2-axis are not correct; height of the head is not correct
REMEDY
● Adjust the minimum/maximum positions and zero point correction correctly; specify the head
height correctly.
1053 Z-axis; GU3: Target position outside of travel range
CAUSE
● The minimum/maximum positions of the Z3-axis are not correct; height of the head is not correct
REMEDY
● Adjust the minimum/maximum positions and zero point correction correctly; specify the head
height correctly.
1054 Z-axis; GU1: BERO for position monitoring off
CAUSE
● When the gantry moves the Z1-axis is not at the top; alignment of the Bero is faulty; Bero is defec-
tive
axis is jamming; motor, controller, servo defective
REMEDY
● Inspect and if necessary repair or replace the components just mentioned
1055 Z-axis; GU2: BERO for position monitoring off
CAUSE
● When the gantry moves the Z2-axis is not at the top; alignment of the Bero is faulty; Bero is defec-
tive
axis is jamming; motor, controller, servo defective
REMEDY
● Inspect and if necessary repair or replace the components just mentioned