00191494-01 - 第105页
Short Reference SIPLACE 80 S-15/F3/G Error Messages 03/99 Issue Software Version SR.010.x x 103 1056 Z-axis; GU3: BERO for position moni toring off CAUSE ● When the gant ry moves the Z3-axis is not a t the top; alignment…
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
102
1050 yk-axis: Target position outside of travel range
CAUSE
● The measurement of the head references does not match the travel range of the yk-axis
REMEDY
● Remeasure the head references; remeasure the minimum/maximum positions of the yk-axis
1051 Z-axis; GU1: Target position outside of travel range
CAUSE
● The minimum/maximum positions of the Z1-axis are not correct; height of the head is not correct
REMEDY
● Adjust the minimum/maximum positions and zero point correction correctly; specify the head
height correctly.
1052 Z-axis; GU2: Target position outside of travel range
CAUSE
● The minimum/maximum positions of the Z2-axis are not correct; height of the head is not correct
REMEDY
● Adjust the minimum/maximum positions and zero point correction correctly; specify the head
height correctly.
1053 Z-axis; GU3: Target position outside of travel range
CAUSE
● The minimum/maximum positions of the Z3-axis are not correct; height of the head is not correct
REMEDY
● Adjust the minimum/maximum positions and zero point correction correctly; specify the head
height correctly.
1054 Z-axis; GU1: BERO for position monitoring off
CAUSE
● When the gantry moves the Z1-axis is not at the top; alignment of the Bero is faulty; Bero is defec-
tive
axis is jamming; motor, controller, servo defective
REMEDY
● Inspect and if necessary repair or replace the components just mentioned
1055 Z-axis; GU2: BERO for position monitoring off
CAUSE
● When the gantry moves the Z2-axis is not at the top; alignment of the Bero is faulty; Bero is defec-
tive
axis is jamming; motor, controller, servo defective
REMEDY
● Inspect and if necessary repair or replace the components just mentioned
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
103
1056 Z-axis; GU3: BERO for position monitoring off
CAUSE
● When the gantry moves the Z3-axis is not at the top; alignment of the Bero is faulty; Bero is defec-
tive
axis is jamming; motor, controller, servo defective
REMEDY
● Inspect and if necessary repair or replace the components just mentioned
1071 X-axis error: deactivated
CAUSE
● Axis has been deactivated at the axis board (servo)
REMEDY
● Switch the axis on at the axis board
1072 Y-axis error: deactivated
CAUSE
● Axis has been deactivated at the axis board (servo)
REMEDY
● Switch the axis on at the axis board
1073 xk-axis error: deactivated
CAUSE
● Axis has been deactivated at the axis board (servo)
REMEDY
● Switch the axis on at the axis board
1074 yk-axis error: deactivated
CAUSE
● Axis has been deactivated at the axis board (servo)
REMEDY
● Switch the axis on at the axis board
1075 Z-axis error; GU1: deactivated
CAUSE
● Axis has been deactivated at the axis board (servo)
REMEDY
● Switch the axis on at the axis board
1076 Z-axis error; GU2: deactivated
CAUSE
● Axis has been deactivated at the axis board (servo)
REMEDY
● Switch the axis on at the axis board
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
104
1077 Z-axis error; GU3: deactivated
CAUSE
● Axis has been deactivated at the axis board (servo)
REMEDY
● Switch the axis on at the axis board
1085 X-axis error: undefined position type
CAUSE
● Software error; should not occur
An incorrect or invalid positioning type has been specified in the machine data
REMEDY
● Check machine data
1086 Y-axis error: undefined position type
CAUSE
● Software error; should not occur
An incorrect or invalid positioning type has been specified in the machine data
REMEDY
● Check machine data
1087 xk-axis error: undefined position type
CAUSE
● Software error; should not occur
An incorrect or invalid positioning type has been specified in the machine data
REMEDY
● Check machine data
1088 yk-axis error: undefined position type
CAUSE
● Software error; should not occur
An incorrect or invalid positioning type has been specified in the machine data
REMEDY
● Check machine data
1089 Z-axis error; GU1: undefined position type
CAUSE
● Software error; should not occur
An incorrect or invalid positioning type has been specified in the machine data
REMEDY
● Check machine data