00191494-01 - 第107页

Short Reference SIPLACE 80 S-15/F3/G Error Messages 03/99 Issue Software Version SR.010.x x 105 1090 Z-axis error; GU2: undefined positio n type CAUSE ● Software error; should not oc cur An incorrect or invalid position …

100%1 / 124
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
104
1077 Z-axis error; GU3: deactivated
CAUSE
Axis has been deactivated at the axis board (servo)
REMEDY
Switch the axis on at the axis board
1085 X-axis error: undefined position type
CAUSE
Software error; should not occur
An incorrect or invalid positioning type has been specified in the machine data
REMEDY
Check machine data
1086 Y-axis error: undefined position type
CAUSE
Software error; should not occur
An incorrect or invalid positioning type has been specified in the machine data
REMEDY
Check machine data
1087 xk-axis error: undefined position type
CAUSE
Software error; should not occur
An incorrect or invalid positioning type has been specified in the machine data
REMEDY
Check machine data
1088 yk-axis error: undefined position type
CAUSE
Software error; should not occur
An incorrect or invalid positioning type has been specified in the machine data
REMEDY
Check machine data
1089 Z-axis error; GU1: undefined position type
CAUSE
Software error; should not occur
An incorrect or invalid positioning type has been specified in the machine data
REMEDY
Check machine data
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
105
1090 Z-axis error; GU2: undefined position type
CAUSE
Software error; should not occur
An incorrect or invalid positioning type has been specified in the machine data
REMEDY
Check machine data
1091 Z-axis error; GU3: undefined position type
CAUSE
Software error; should not occur
An incorrect or invalid positioning type has been specified in the machine data
REMEDY
Check machine data
1092 X-axis error: limit switch actuated
CAUSE
The axis is located at the limit switch or limit switch was actuated
REMEDY
Slide the axis away from the limit switch and re-reference; switch the machine off and back on
again
1093 Y-axis error: limit switch actuated
CAUSE
The axis is located at the limit switch or limit switch was actuated
REMEDY
Slide the axis away from the limit switch and re-reference; switch the machine off and back on
again
1094 xk-axis error: limit switch actuated
CAUSE
The axis is located at the limit switch or limit switch was actuated
REMEDY
Slide the axis away from the limit switch and re-reference; switch the machine off and back on
again
1095 yk-axis error: limit switch actuated
CAUSE
The axis is located at the limit switch or limit switch was actuated
REMEDY
Slide the axis away from the limit switch and re-reference; switch the machine off and back on
again
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
106
1096 Z-axis error; GU1: limit switch actuated
CAUSE
The axis is located at the limit switch or limit switch was actuated
REMEDY
Slide the axis away from the limit switch and re-reference; switch the machine off and back on
again
1097 Z-axis error; GU2: limit switch actuated
CAUSE
The axis is located at the limit switch or limit switch was actuated
REMEDY
Slide the axis away from the limit switch and re-reference; switch the machine off and back on
again
1098 Z-axis error; GU3: limit switch actuated
CAUSE
The axis is located at the limit switch or limit switch was actuated
REMEDY
Slide the axis away from the limit switch and re-reference; switch the machine off and back on
again
1099 X-axis error: Target position outside of travel range
CAUSE
Program error; should not occur
REMEDY
1100 Y-axis error: Target position outside of travel range
CAUSE
Program error; should not occur
REMEDY
1101 xk-axis error: Target position outside of travel range
CAUSE
Program error; should not occur
REMEDY
1102 yk-axis error: Target position outside of travel range
CAUSE
Program error; should not occur
REMEDY