00191494-01 - 第111页
Short Reference SIPLACE 80 S-15/F3/G Error Messages 03/99 Issue Software Version SR.010.x x 109 1 1 17 Z-axis error; GU1: incorrect prece ding sign CAUSE ● Program error; should not occ ur REMEDY ● 1 1 18 Z-axis error; G…
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
108
1110 Z-axis error; GU1: incorrect character
CAUSE
● Program error; should not occur
REMEDY
●
1111 Z-axis error; GU2: incorrect character
CAUSE
● Program error; should not occur
REMEDY
●
1112 Z-axis error; GU3: incorrect character
CAUSE
● Program error; should not occur
REMEDY
●
1113 X-axis error: incorrect preceding sign
CAUSE
● Program error; should not occur
REMEDY
●
1114 Y-axis error: incorrect preceding sign
CAUSE
● Program error; should not occur
REMEDY
●
1115 xk-axis error: incorrect preceding sign
CAUSE
● Program error; should not occur
REMEDY
●
1116 yk-axis error: incorrect preceding sign
CAUSE
● Program error; should not occur
REMEDY
●
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
109
1117 Z-axis error; GU1: incorrect preceding sign
CAUSE
● Program error; should not occur
REMEDY
●
1118 Z-axis error; GU2: incorrect preceding sign
CAUSE
● Program error; should not occur
REMEDY
●
1119 Z-axis error; GU3: incorrect preceding sign
CAUSE
● Program error; should not occur
REMEDY
●
1120 X-axis error: Reference error
CAUSE
● Invalid reference point type in the machine data
REMEDY
● Check machine data
1121 Y-axis error: Reference error
CAUSE
● Invalid reference point type in the machine data
REMEDY
● Check machine data
1122 xk-axis error: Reference error
CAUSE
● Invalid reference point type in the machine data
REMEDY
● Check machine data
1123 yk-axis error: Reference error
CAUSE
● Invalid reference point type in the machine data
REMEDY
● Check machine data
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
110
1124 Z-axis error, GU1: Reference error
CAUSE
● Invalid reference point type in the machine data
REMEDY
● Check machine data
1125 Z-axis error; GU2: Reference error
CAUSE
● Invalid reference point type in the machine data
REMEDY
● Check machine data
1126 Z-axis error, GU3: Reference error
CAUSE
● Invalid reference point type in the machine data
REMEDY
● Check machine data
1127 X-axis error: incorrect acceleration
CAUSE
● Invalid value in the machine data
REMEDY
● Check the machine data
1128 Y-axis error: incorrect acceleration
CAUSE
● Invalid value in the machine data
REMEDY
● Check the machine data
1129 xk-axis error: incorrect acceleration
CAUSE
● Invalid value in the machine data
REMEDY
● Check the machine data
1130 yk-axis error: incorrect acceleration
CAUSE
● Invalid value in the machine data
REMEDY
● Check the machine data