00191494-01 - 第118页
Error Messages Short Reference SIPLACE 80 S-15/F3/G 03/99 Issue Software Version SR.010.x x 116 1 165 GU: Error while setting desir ed temperature CAUSE ● While the desired tempe rature was being sent to th e GU an error…
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
115
1159 GU: incorrect record number during Receive
CAUSE
● When receiving process data from the GU the record sum was not correct. Software error in the
GU
REMEDY
● Siemens Service should be notified
1160 GU: incorrect number of records
CAUSE
● When receiving process data from the GU the record sum was not correct. Software error in the
GU
REMEDY
● Siemens Service should be notified
1161 GU: Error during Reserve
CAUSE
● While reserving the interface for the GU an error occurred. Software error
REMEDY
● Siemens Service should be notified
1162 GU: Error during Release
CAUSE
● While releasing the interface for the GU an error occurred. Software error
REMEDY
● Siemens Service should be notified
1163 GU: Glueing order to head
CAUSE
● While the glueing order was being sent to the GU an error occurred
REMEDY
● Error is specified more precisely in a further message. Take this into account during troubleshoo-
ting
1164 GU: wait until glueing is finished
CAUSE
● While waiting for the end message from the glueing unit an error occurred
REMEDY
● Error is specified more precisely in a further message. Take this into account during troubleshoo-
ting
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
116
1165 GU: Error while setting desired temperature
CAUSE
● While the desired temperature was being sent to the GU an error occurred
REMEDY
● Error is specified more precisely in a further message. Take this into account during troubleshoo-
ting
1166 GU: Error while setting glueing point volume
CAUSE
● While the glueing point volume change was being sent to the GU an error occurred
REMEDY
● Error is specified more precisely in a further message. Take this into account during troubleshoo-
ting
1167 GU: Error while setting new cartridge
CAUSE
● An error occurred while a command was being sent to the GU that a new cartridge had been
inserted.
REMEDY
● Error is specified more precisely in a further message. Take this into account during troubleshoo-
ting
1168 GU: Error while reading actual temperature
CAUSE
● While the actual temperature was being requested for the GU an error occurred
REMEDY
● Error is specified more precisely in a further message. Take this into account during troubleshoo-
ting
1169 GU: Error during Switch on continuous glueing
CAUSE
● While the continuous glueing of the GU was being switched on an error occurred
REMEDY
● Error is specified more precisely in a further message. Take this into account during troubleshoo-
ting
1170 GU: Error during Switch off continuous glueing
CAUSE
● While the continuous glueing of the GU was being switched off an error occurred
REMEDY
● Error is specified more precisely in a further message. Take this into account during troubleshoo-
ting
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
117
1171 Error during Send
INI data
to GU
CAUSE
● An error occurred while .ini data was being sent to the GU
REMEDY
● Error is specified more precisely in a further message. Take this into account during troubleshoo-
ting
1172 GU: Error during Send process data
CAUSE
● An error occurred while process data was being sent to the GU.
REMEDY
● Error is specified more precisely in a further message. Take this into account during troubleshoo-
ting
1173 GU: Error during Receive process data
CAUSE
● An error occurred while process data was being received by the GU.
REMEDY
● Error is specified more precisely in a further message. Take this into account during troubleshoo-
ting
1174 WARNING: Fill cartridge before next PCB
CAUSE
● Bero for "Empty cartridge" triggered; not enough glue left to glue the next board
REMEDY
● Change cartridge and confirm
1175 Cartridge empty; PCB will not be processed
CAUSE
● This was preceded by error 1174 and the cartridge was still not changed
REMEDY
● Change cartridge and confirm
1176 Cleaning process must be started
CAUSE
● One of the cleaning conditions has occurred. Not an error
REMEDY
● The machine cleans itself automatically
1177 GU: Software error in RIO call
CAUSE
● Software error
REMEDY
● Siemens Service should be notified