00191494-01 - 第118页

Error Messages Short Reference SIPLACE 80 S-15/F3/G 03/99 Issue Software Version SR.010.x x 116 1 165 GU: Error while setting desir ed temperature CAUSE ● While the desired tempe rature was being sent to th e GU an error…

100%1 / 124
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
115
1159 GU: incorrect record number during Receive
CAUSE
When receiving process data from the GU the record sum was not correct. Software error in the
GU
REMEDY
Siemens Service should be notified
1160 GU: incorrect number of records
CAUSE
When receiving process data from the GU the record sum was not correct. Software error in the
GU
REMEDY
Siemens Service should be notified
1161 GU: Error during Reserve
CAUSE
While reserving the interface for the GU an error occurred. Software error
REMEDY
Siemens Service should be notified
1162 GU: Error during Release
CAUSE
While releasing the interface for the GU an error occurred. Software error
REMEDY
Siemens Service should be notified
1163 GU: Glueing order to head
CAUSE
While the glueing order was being sent to the GU an error occurred
REMEDY
Error is specified more precisely in a further message. Take this into account during troubleshoo-
ting
1164 GU: wait until glueing is finished
CAUSE
While waiting for the end message from the glueing unit an error occurred
REMEDY
Error is specified more precisely in a further message. Take this into account during troubleshoo-
ting
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
116
1165 GU: Error while setting desired temperature
CAUSE
While the desired temperature was being sent to the GU an error occurred
REMEDY
Error is specified more precisely in a further message. Take this into account during troubleshoo-
ting
1166 GU: Error while setting glueing point volume
CAUSE
While the glueing point volume change was being sent to the GU an error occurred
REMEDY
Error is specified more precisely in a further message. Take this into account during troubleshoo-
ting
1167 GU: Error while setting new cartridge
CAUSE
An error occurred while a command was being sent to the GU that a new cartridge had been
inserted.
REMEDY
Error is specified more precisely in a further message. Take this into account during troubleshoo-
ting
1168 GU: Error while reading actual temperature
CAUSE
While the actual temperature was being requested for the GU an error occurred
REMEDY
Error is specified more precisely in a further message. Take this into account during troubleshoo-
ting
1169 GU: Error during Switch on continuous glueing
CAUSE
While the continuous glueing of the GU was being switched on an error occurred
REMEDY
Error is specified more precisely in a further message. Take this into account during troubleshoo-
ting
1170 GU: Error during Switch off continuous glueing
CAUSE
While the continuous glueing of the GU was being switched off an error occurred
REMEDY
Error is specified more precisely in a further message. Take this into account during troubleshoo-
ting
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
117
1171 Error during Send
INI data
to GU
CAUSE
An error occurred while .ini data was being sent to the GU
REMEDY
Error is specified more precisely in a further message. Take this into account during troubleshoo-
ting
1172 GU: Error during Send process data
CAUSE
An error occurred while process data was being sent to the GU.
REMEDY
Error is specified more precisely in a further message. Take this into account during troubleshoo-
ting
1173 GU: Error during Receive process data
CAUSE
An error occurred while process data was being received by the GU.
REMEDY
Error is specified more precisely in a further message. Take this into account during troubleshoo-
ting
1174 WARNING: Fill cartridge before next PCB
CAUSE
Bero for "Empty cartridge" triggered; not enough glue left to glue the next board
REMEDY
Change cartridge and confirm
1175 Cartridge empty; PCB will not be processed
CAUSE
This was preceded by error 1174 and the cartridge was still not changed
REMEDY
Change cartridge and confirm
1176 Cleaning process must be started
CAUSE
One of the cleaning conditions has occurred. Not an error
REMEDY
The machine cleans itself automatically
1177 GU: Software error in RIO call
CAUSE
Software error
REMEDY
Siemens Service should be notified