Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
118
1178 Actual temperature does not reach desired temp.
CAUSE
Glueing parameter controller did not reach the desired temperature
REMEDY
Hardware should be checked
1179 Glue cleaning pad paper finished
CAUSE
Glue cleaning pad finished
REMEDY
Insert new paper
1180 Z-axis, GU1: Bero not activated during upward movement
CAUSE
Z-axis is not moving upwards (sluggish); the bero is defective or set incorrectly
REMEDY
Check the mechanism; check the bero; check the incremental transducer.
1181 Z-axis, GU2: Bero not activated during upward movement
CAUSE
Z-axis is not moving upwards (sluggish); the bero is defective or set incorrectly
REMEDY
Check the mechanism; check the bero; check the incremental transducer.
1182 Z-axis, GU3: Bero not activated during upward movement
CAUSE
Z-axis is not moving upwards (sluggish); the bero is defective or set incorrectly
REMEDY
Check the mechanism; check the bero; check the incremental transducer.
1183 Z-axis, GU1: Bero not released when axis at bottom
CAUSE
Z-axis is not moving downwards (sluggish); the bero is defective or set incorrectly
REMEDY
Check the mechanism; check the bero; check the incremental transducer.
1184 Z-axis, GU2: Bero not released when axis at bottom
CAUSE
Z-axis is not moving downwards (sluggish); the bero is defective or set incorrectly
REMEDY
Check the mechanism; check the bero; check the incremental transducer.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
119
1185 Z-axis, GU3: Bero not released when axis at bottom
CAUSE
Z-axis is not moving downwards (sluggish); the bero is defective or set incorrectly
REMEDY
Check the mechanism; check the bero; check the incremental transducer.
1186 Pressure build-up faulty
CAUSE
The glue cartridge is missing; the compressed air supply to the dispenser unit is inadequate;
the valve (actuation) is defective
REMEDY
Insert cartridge; check the compressed air supply, hoses, valve
1187 Pressure reduction faulty
CAUSE
The venting valve (actuation) is defective
REMEDY
Check the valve and hoses
1188 Glue spot check: error during meas. description generation
CAUSE
Target diameter of the glue spots in the VKL file are outside the permitted range (0 < or < 3 mm)
Camera data (MA data) conversion factor pixels => µm erroneous
REMEDY
Check data
1189 Glue spot check: error during measurement description loading
CAUSE
Transmission error with the MVS vision system; possibly incorrect Eprom version
REMEDY
Check Eprom version
1190 Glue spot check: error during visualization of results
CAUSE
Transmission error with MVS vision system
REMEDY
Check vision system
1191 Glue spot check: measurements start error
CAUSE
Transmission error with MVS vision system
REMEDY
Check vision system
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
120
1192 Glue spot check: error in measurement results
CAUSE
Possibly incorrect Eprom version; otherwise software error
REMEDY
Check Eprom version
1193 Glue spots too large for calculating volume adaption
CAUSE
The size of glue spots is outside the control range for volume adaption (-5....+5); incorrect gluing
station configuration
REMEDY
Check process parameters: nozzle diameter, spacer, temperature;
check gluing station configuration
1194 Glue spot check: no evaluation due to low qual.
CAUSE
The shape or contrast of the glue spot was not good enough for the glue spot check.
REMEDY
Check the gluing needle (defective, dirty).
The glue is leaving threads (check glue temperature)
Color of the glue is not satisfactory (for example, white glue), leading to poor contrast with the
glue scraper roller where the glue spot check is made.
1195 Glue spots too small for calculating volume adaption
CAUSE
The size of glue spots is outside the control range for volume adaption (-5....+5); incorrect gluing
station configuration
REMEDY
Check process parameters: nozzle diameter, spacer, temperature;
check gluing station configuration
1196 Dots of glue too large
CAUSE
Glue dot size is outside correction range.
TO RECTIFY
Check glue nozzle and spacer. Replace glue cartridge. Check glue characteristics.
1197 Dots of glue too small
CAUSE
Glue dot size is outside correction range.
TO RECTIFY
Check glue nozzle and spacer and clean glue nozzle. Replace glue cartridge. Check glue charac-
teristics.