00191494-01 - 第14页
Error Messages Short Reference SIPLACE 80 S-15/F3/G 03/99 Issue Software Version SR.010.x x 12 137 Not enough garages in chang er magazine for nozzle retu rn. SP CAUSE ● Nozzles should be retu rned ⇒ With optical garage …
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
11
125 Coplanarity: clamping of Z-axis does not work
CAUSE
● Clamping reacts too slow; clamping is defective.
REMEDY
● Operate clamping repeatedly; check clamping.
126 Unknown telegram to table
CAUSE
● Obsolete
TISCH.HEX
file.
REMEDY
● Update
TISCH.HEX
file.
129 Communication table-feeder interrupted
CAUSE
● Since the last booting, the connection with the conveyor has been interrupted; the conveyor is not
plugged in; cable is defective.
REMEDY
● Plug in the conveyor; check the cable.
130 Communication table-feeder disturbed
CAUSE
● Communication between table and conveyor is interrupted from time to time; the cable is defec-
tive; the conveyor has been unplugged.
REMEDY
● Plug in the conveyor; check the cable and plug.
132 Foil torn
CAUSE
● The cover foil is torn; the foil removal force has been set incorrectly; the conveyor is defective.
REMEDY
● Repair the foil; adjust removal springs; replace the conveyor.
133 Foil not removed
CAUSE
● The cover foil is not being stripped off; the foil removal force has been set incorrectly; the con-
veyor is defective.
REMEDY
● Pull off the foil by hand; set removal spring
134 Transport in feeder disturbed
CAUSE
● Tape backing up; the conveyor is defective
REMEDY
● Remove tape back-up; replace the conveyor
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
12
137 Not enough garages in changer magazine for nozzle return. SP
CAUSE
● Nozzles should be returned ⇒
With optical garage check: all garages were checked with the board camera and are occupied.
Without optical garage check: there are not enough empty garages available for the nozzles to be
returned.
REMEDY
● Takes place automatically: all nozzles which could not be returned are rejected.
138 Insuff. number of nozzles in changer magazine SP to pick up
CAUSE
● Nozzles are to be picked up ⇒
With optical garage check: All garages have been checked with the board camera and are empty
Without optical garage check: One or more garages of the required nozzle type is empty.
REMEDY
● The corresponding magazines must be set full via the menu.
139 No cluster available for nozzle pick-up SP
CAUSE
● No cluster has been specified as specified selection.
REMEDY
● Specifiy placement program in the line computer.
140 Nozzle-changer SP head cannot be unlocked
CAUSE
● Key plate for locking the nozzle-changer magazine cannot be unlocked.
The plate is jamming mechanically, due to components etc.
Incorrect compressed air setting for the actuating cylinder; lacking air pressure;
the cylinder or valve is defective.
REMEDY
● Correction of the above causes
141 Nozzle-changer SP head cannot be locked
CAUSE
● Key plate for locking the nozzle-changer magazine cannot be unlocked.
The plate is jamming mechanically, due to components etc.
Incorrect compressed air setting for the actuating cylinder; lacking air pressure;
the cylinder or valve is defective.
REMEDY
● Correction of the above causes
142 Communication with vision system during nozzle check faulty
CAUSE
● Communication with the vision system is faulty.
REMEDY
● Switch the system on and off (reset); notify Siemens Service Department.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
13
143 Desired Z-axis position exceeded during nozzle SP pick-up
CAUSE
● The position of the x and y axes in the machine data is not correct;
the desired position of the Z-axis is not correct; there is no nozzle in the garage.
REMEDY
● Correction of the above causes
144 Desired Z-axis position not reached during nozzle SP pick-up
CAUSE
● The position of the x and y axes in the machine data is not correct (sleeve is not positioned over
the garage);
desired position of the Z-axis is not correct; there is already a nozzle at the sleeve.
REMEDY
● Correction of the above causes
145 Desired Z-axis position exceeded during nozzle SP return
CAUSE
● The position of the x and y axes in the machine data is not correct;
desired position of the Z-axis is not correct; there is no nozzle at the sleeve.
REMEDY
● Correction of the above causes
146 Desired Z-axis position not reached during nozzle SP return
CAUSE
● The position of the x and y axes in the machine data is not correct (sleeve is not positioned over
the garage);
desired position of the Z-axis is not correct; there is already a nozzle in the garage.
REMEDY
● Correction of the above cause
147 Desired Z-axis position exceeded during nozzle SP rejection
CAUSE
● The position of the x and y axes in the machine data is not correct ;
desired position of the Z-axis is not correct; there is no nozzle at the sleeve.
REMEDY
● Correction of the above causes
148 Desired Z-axis position not reached during nozzle SP rejection
CAUSE
● The position of the x and y axes in the machine data is not correct (sleeve not above garage);
desired position of the Z-axis is not correct; there is already a nozzle in the garage.
REMEDY
● Correction of the above causes