Error Messages Short Reference SIPLACE 80 S-15/F3/G 03/99 Issue Software Version SR.010.x x 14 149 Nozzle SP change not comple ted CAUSE ● This error mess age is issued when after an automatic change the actual sta te of…

100%1 / 124
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
13
143 Desired Z-axis position exceeded during nozzle SP pick-up
CAUSE
The position of the x and y axes in the machine data is not correct;
the desired position of the Z-axis is not correct; there is no nozzle in the garage.
REMEDY
Correction of the above causes
144 Desired Z-axis position not reached during nozzle SP pick-up
CAUSE
The position of the x and y axes in the machine data is not correct (sleeve is not positioned over
the garage);
desired position of the Z-axis is not correct; there is already a nozzle at the sleeve.
REMEDY
Correction of the above causes
145 Desired Z-axis position exceeded during nozzle SP return
CAUSE
The position of the x and y axes in the machine data is not correct;
desired position of the Z-axis is not correct; there is no nozzle at the sleeve.
REMEDY
Correction of the above causes
146 Desired Z-axis position not reached during nozzle SP return
CAUSE
The position of the x and y axes in the machine data is not correct (sleeve is not positioned over
the garage);
desired position of the Z-axis is not correct; there is already a nozzle in the garage.
REMEDY
Correction of the above cause
147 Desired Z-axis position exceeded during nozzle SP rejection
CAUSE
The position of the x and y axes in the machine data is not correct ;
desired position of the Z-axis is not correct; there is no nozzle at the sleeve.
REMEDY
Correction of the above causes
148 Desired Z-axis position not reached during nozzle SP rejection
CAUSE
The position of the x and y axes in the machine data is not correct (sleeve not above garage);
desired position of the Z-axis is not correct; there is already a nozzle in the garage.
REMEDY
Correction of the above causes
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
14
149 Nozzle SP change not completed
CAUSE
This error message is issued when after an automatic change the actual state of the nozzle confi-
guration does not yet correspond with the desired state.
REMEDY
In the menu "Display errors" list the error and case by case:
set the magazine(s) full;
set up nozzle-changer;
select the menu "Pick up all nozzles";
NOTE
While this is running when there is a fault the magazine and garage numbers will be displayed in the
"General errors" menu.
The following will apply: Info1 = Magazine number
Info2 = Garage number
150 Nozzle SP pick-up not completed
CAUSE
During automatic change or when the "Pick up all nozzles" menu was called it was not possible to
pick up all nozzles because:
there are too few nozzles in the corresponding magazine;.
the magazine is empty or was not installed.
REMEDY
In the menu "Display error" list the error and case by case:
set the magazine(s) full;
set up nozzle-changer;
select the menu "Pick up all nozzles";
NOTE
While this is running when there is a fault the magazine and garage numbers will be displayed in the
"General errors" menu.
The following will apply: Info1 = Magazine number
Info2 = Garage number
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
15
151 Nozzle return/discard SP not completed
CAUSE
During automatic change or when the "Return all nozzles" menu was called it was not possible to
return all nozzles because:
there are no enough empty garages in the corresponding magazine.
although the magazine is full, setting full was not confirmed.
REMEDY
Nozzles which could not be returned will be ejected into the rejects tray.
NOTE
While this is running when there is a fault the magazine and garage numbers will be displayed in the
"General errors" menu.
The following will apply: Info1 = Magazine number
Info2 = Garage number
153 Ceramic substrate centering: x clamp cannot be opened
CAUSE
Air pressure is absent; valve incorrectly set; bero defective; mechanical problems
REMEDY
Check air pressure; adjust valve; check bero; check mechanism
154 Ceramic substrate centering: x clamp cannot be locked
CAUSE
Valve set incorrectly; bero defective; mechanical problems
REMEDY
Adjust valve; check bero; check mechanism
155 Conveyor belt target width outside travel range
CAUSE
Conveyor belt target width specified by the line computer for the automatic width adjustment is
> 460 mm or < 50 mm
REMEDY
Input the target width of the board (which will lie within the minimum and maximum target widths)
into the line computer
156 Conveyor belt target width cannot be set (timeout)
CAUSE
Emergency stop during automatic width adjustment; bero on the moveable side of the conveyor is
defective or not set correctly; width adjustment motor is defective
REMEDY
Check bero or motor