Error Messages Short Reference SIPLACE 80 S-15/F3/G 03/99 Issue Software Version SR.010.x x 18 207 Fault in placement stat. durin g vac. meas. CAUSE ● Suction face of the no zzle damaged; nozzle too small; jaws of the ce…
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
17
201 Track empty, optical centering incorrect
CAUSE
● 3 optical measuring errors with component from one track; set up for incorrect component.
Incorrect angle has been input for the component in the feeder.
REMEDY
● Check components feed; fill up empty track and reset track.
check set-up data.
202 Track empty, measure value outside tol.
CAUSE
● 3 electrical measurement errors with component from one track
REMEDY
● Check components feed; fill up empty track and reset track.
203 Track put out of operation by operator
CAUSE
● Under the menu "Refill" track set to empty.
REMEDY
● Reset track in the menu "Refill".
204 Z-axis cannot be moved upwards
CAUSE
● When the start button pressed Z-axis not in top position.
REMEDY
● Check servo, push Z-axis upwards by hand.
205 BERO for Z-axis top position not released
CAUSE
● Sensing distance too great; Bero defective; cam disk not tightened up correctly; z zero point cor-
rection value incorrect; counting error.
REMEDY
● Adjust sensing distance; replace Bero; tighten up cam disk; redetermine z zero point correction;
fit new motor/tacho/encoder; carry out axis calibration.
206 Fault in pick-up station during vac. meas.
CAUSE
● Suction face of the nozzle damaged; nozzle too small; component was not supplied.
REMEDY
● Fit new nozzle; check component feed.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
18
207 Fault in placement stat. during vac. meas.
CAUSE
● Suction face of the nozzle damaged; nozzle too small; jaws of the centering station bouncing;
component was not picked up properly; vacuum in the holding circuit too low; vacuum board
defective.
REMEDY
● Fit new nozzle; calibration of the motor control board; check component feed, call Siemens Ser-
vice.
208 End position BERO of centering station not being actuated
CAUSE
● End position Bero defective or incorrectly set; recuperator spring of the centering station worn
out.
REMEDY
● Fit new Bero, adjust; maintain centering station.
209 Counting error X-axis
CAUSE
● Scales dirty (incremental encoder).
REMEDY
● Clean scales (incremental encoder).
210 Measurement trigger BERO of centering station not actuated
CAUSE
● Distance between Bero and actuator flag too great; Bero defective
REMEDY
● Correct distance to actuator flag; fit new Bero.
211 Counting error Y-axis
CAUSE
● Scales dirty (incremental encoder).
REMEDY
● Clean scales (incremental encoder).
212 Fault during vacuum measuring in reject position
CAUSE
● O-ring on the sealing piston damaged.
REMEDY
● Fit new O-ring to the sealing piston.
213 Timeout during reception from coplanarity
CAUSE
● Coplanarity module not plugged in
REMEDY
● Plug in module
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
19
214 Check sum error of answer from coplanarity
CAUSE
● Error in the response from coplanarity.
REMEDY
● Check the supply voltage of the coplanarity module check; repeat measurement.
215 Position control of S-axis does not work
CAUSE
● The position control of the axis is not working correctly.
REMEDY
● Switch off the machine (reset); check axis for stiffness.
216 Position control of X-axis does not work
CAUSE
● The position control of the axis is not working correctly.
REMEDY
● Switch off the machine (reset); check axis for stiffness.
217 Position control of Y-axis does not work
CAUSE
● The position control of the axis is not working correctly.
REMEDY
● Switch off the machine (reset); check axis for stiffness.
218 Answer from coplanarity has no STX
CAUSE
● The first character of the answer from coplanarity is lost.
REMEDY
● Check supply voltage; check jumper of the coplanarity module; repeat measurement.
219 Coplan.: Communication buffer overflow on MC
CAUSE
● Too many measurement data for one component
REMEDY
● Inform Siemens Service.
220 Coplanarity cannot execute command
CAUSE
● Wrong command was sent to the coplanarity module; coplanarity was not initialized
error during execution; package form data erroneous.
REMEDY
● Switch machine off and back on; respecify set-up; check package form data.