Short Reference SIPLACE 80 S-15/F3/G Error Messages 03/99 Issue Software Version SR.010.x x 19 214 Check sum error of answer from c oplanarity CAUSE ● Error in the response from cop lanarity . REMEDY ● Check the supply v…
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
18
207 Fault in placement stat. during vac. meas.
CAUSE
● Suction face of the nozzle damaged; nozzle too small; jaws of the centering station bouncing;
component was not picked up properly; vacuum in the holding circuit too low; vacuum board
defective.
REMEDY
● Fit new nozzle; calibration of the motor control board; check component feed, call Siemens Ser-
vice.
208 End position BERO of centering station not being actuated
CAUSE
● End position Bero defective or incorrectly set; recuperator spring of the centering station worn
out.
REMEDY
● Fit new Bero, adjust; maintain centering station.
209 Counting error X-axis
CAUSE
● Scales dirty (incremental encoder).
REMEDY
● Clean scales (incremental encoder).
210 Measurement trigger BERO of centering station not actuated
CAUSE
● Distance between Bero and actuator flag too great; Bero defective
REMEDY
● Correct distance to actuator flag; fit new Bero.
211 Counting error Y-axis
CAUSE
● Scales dirty (incremental encoder).
REMEDY
● Clean scales (incremental encoder).
212 Fault during vacuum measuring in reject position
CAUSE
● O-ring on the sealing piston damaged.
REMEDY
● Fit new O-ring to the sealing piston.
213 Timeout during reception from coplanarity
CAUSE
● Coplanarity module not plugged in
REMEDY
● Plug in module
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
19
214 Check sum error of answer from coplanarity
CAUSE
● Error in the response from coplanarity.
REMEDY
● Check the supply voltage of the coplanarity module check; repeat measurement.
215 Position control of S-axis does not work
CAUSE
● The position control of the axis is not working correctly.
REMEDY
● Switch off the machine (reset); check axis for stiffness.
216 Position control of X-axis does not work
CAUSE
● The position control of the axis is not working correctly.
REMEDY
● Switch off the machine (reset); check axis for stiffness.
217 Position control of Y-axis does not work
CAUSE
● The position control of the axis is not working correctly.
REMEDY
● Switch off the machine (reset); check axis for stiffness.
218 Answer from coplanarity has no STX
CAUSE
● The first character of the answer from coplanarity is lost.
REMEDY
● Check supply voltage; check jumper of the coplanarity module; repeat measurement.
219 Coplan.: Communication buffer overflow on MC
CAUSE
● Too many measurement data for one component
REMEDY
● Inform Siemens Service.
220 Coplanarity cannot execute command
CAUSE
● Wrong command was sent to the coplanarity module; coplanarity was not initialized
error during execution; package form data erroneous.
REMEDY
● Switch machine off and back on; respecify set-up; check package form data.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
20
221 Programmed position of X-axis outside travel range
CAUSE
● Error in the local machine data (location fiducials).
REMEDY
● Check the fiducial data in the machine data.
222 Programmed position of Y-axis outside travel range
CAUSE
● Error in the local machine data (location fiducials).
REMEDY
● Check the fiducial data in the machine data.
226 Vacuum of pick-up circuit not within range
CAUSE
● Segments dirty; vacuum not working properly; limits specified too low; vacuum circuit defective.
REMEDY
● Maintain segments; check vacuum; extend limits; check vacuum circuit.
227 Vacuum of reject circuit not within range
CAUSE
● Segments dirty; vacuum not working properly; limits specified too low; vacuum circuit defective.
REMEDY
● Maintain segments; check vacuum; extend limits; check vacuum circuit.
228 Interface signals to the preceding station incorrect
CAUSE
● Interface line not connected; cable defective; interface boards defective.
REMEDY
● Check signal path, replace defective assemblies.
229 The input conveyor light barrier is not covered
CAUSE
● PCB board was removed while program was executing; PCB board jamming; sensor defective.
REMEDY
● Correct the jamming; fit new sensor.
230 The input conveyor light barrier is not released
CAUSE
● PCB board jamming; sensor defective.
REMEDY
● Correct the jamming; fit new sensor.