00191494-01 - 第22页

Error Messages Short Reference SIPLACE 80 S-15/F3/G 03/99 Issue Software Version SR.010.x x 20 221 Programmed position of X-ax is outside travel range CAUSE ● Error in the local machin e data (location fiducials). REMEDY…

100%1 / 124
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
19
214 Check sum error of answer from coplanarity
CAUSE
Error in the response from coplanarity.
REMEDY
Check the supply voltage of the coplanarity module check; repeat measurement.
215 Position control of S-axis does not work
CAUSE
The position control of the axis is not working correctly.
REMEDY
Switch off the machine (reset); check axis for stiffness.
216 Position control of X-axis does not work
CAUSE
The position control of the axis is not working correctly.
REMEDY
Switch off the machine (reset); check axis for stiffness.
217 Position control of Y-axis does not work
CAUSE
The position control of the axis is not working correctly.
REMEDY
Switch off the machine (reset); check axis for stiffness.
218 Answer from coplanarity has no STX
CAUSE
The first character of the answer from coplanarity is lost.
REMEDY
Check supply voltage; check jumper of the coplanarity module; repeat measurement.
219 Coplan.: Communication buffer overflow on MC
CAUSE
Too many measurement data for one component
REMEDY
Inform Siemens Service.
220 Coplanarity cannot execute command
CAUSE
Wrong command was sent to the coplanarity module; coplanarity was not initialized
error during execution; package form data erroneous.
REMEDY
Switch machine off and back on; respecify set-up; check package form data.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
20
221 Programmed position of X-axis outside travel range
CAUSE
Error in the local machine data (location fiducials).
REMEDY
Check the fiducial data in the machine data.
222 Programmed position of Y-axis outside travel range
CAUSE
Error in the local machine data (location fiducials).
REMEDY
Check the fiducial data in the machine data.
226 Vacuum of pick-up circuit not within range
CAUSE
Segments dirty; vacuum not working properly; limits specified too low; vacuum circuit defective.
REMEDY
Maintain segments; check vacuum; extend limits; check vacuum circuit.
227 Vacuum of reject circuit not within range
CAUSE
Segments dirty; vacuum not working properly; limits specified too low; vacuum circuit defective.
REMEDY
Maintain segments; check vacuum; extend limits; check vacuum circuit.
228 Interface signals to the preceding station incorrect
CAUSE
Interface line not connected; cable defective; interface boards defective.
REMEDY
Check signal path, replace defective assemblies.
229 The input conveyor light barrier is not covered
CAUSE
PCB board was removed while program was executing; PCB board jamming; sensor defective.
REMEDY
Correct the jamming; fit new sensor.
230 The input conveyor light barrier is not released
CAUSE
PCB board jamming; sensor defective.
REMEDY
Correct the jamming; fit new sensor.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
21
231 No PCB on the input conveyor
CAUSE
The PCB board was removed while being transported onto the central conveyor; sensor defec-
tive.
REMEDY
Under the menu "Transportation error" continue placement, place board on input conveyor; fit
new sensor.
232 The lifting table cannot be moved downwards
CAUSE
Beros defective; cutout triggered.
REMEDY
fit new Beros; close lifting table cutout.
233 Command to coplanarity is not complete
CAUSE
Package form data, set-up erroneous.
REMEDY
Re-assign set-up, repeat measurement.
234 The lifting table cannot be moved upwards
CAUSE
Beros defective; cutout triggered.
REMEDY
Fit new Beros; close lifting table cutout.
235 Center conveyor light barrier is not released
CAUSE
PCB board jamming in the central conveyor; sensor defective.
REMEDY
Correct the jamming; fit new sensor.
236 PCB does not reach the center conveyor
CAUSE
PCB board jamming in the center conveyor; sensor defective.
REMEDY
Correct the jamming; fit new sensor.
237 Stopper jam during extension
CAUSE
Compressed air lacking; back pressure too high; stopper defective.
REMEDY
Check compressed air; adjust back pressure; replace stopper.