Error Messages Short Reference SIPLACE 80 S-15/F3/G 03/99 Issue Software Version SR.010.x x 24 251 PCB in conveyor, or conveyor running CAUSE ● PCB board on conveyo r during width adjustment. REMEDY ● Remove the PCB boar…

100%1 / 124
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
23
244 Center conveyor occupied
CAUSE
When the function "Board to center conveyor" started there already was a PCB board on the cen-
ter conveyor; sensor defective.
When the belt speed was set the center conveyor was occupied.
REMEDY
Remove the PCB board; fit new sensor.
245 Output conveyor occupied
CAUSE
When the function "Board to output conveyor" started there already was a PCB board on the out-
put conveyor; sensor of output conveyor defective.
When the belt speed was set output conveyor was occupied.
REMEDY
Remove the PCB board; fit new sensor.
246 BERO of left table side is not activated
CAUSE
Bero is not covered.
REMEDY
Check Bero.
247 Error in axis programming (left table side)
CAUSE
Bero of the left table side defective; axis could not be moved.
REMEDY
Check Bero; reboot.
248 BERO of left table side responding constantly
CAUSE
Bero constantly covered.
REMEDY
Check Bero.
249 Width adjustment at limit switch maximum width
CAUSE
Width adjustment moved up to the limit switch; limit switch defective.
REMEDY
Move width adjustment in other direction; fit new limit switch.
250 Width adjustment at limit switch minimum width
CAUSE
Width adjustment moved up to the limit switch; limit switch defective.
REMEDY
Move width adjustment in other direction; fit new limit switch.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
24
251 PCB in conveyor, or conveyor running
CAUSE
PCB board on conveyor during width adjustment.
REMEDY
Remove the PCB board.
252 Software relay for op.voltage defective
CAUSE
Relay K5 defective.
REMEDY
Replace relay K5.
253 No operating voltage
CAUSE
Cover open; start button pressed too briefly.
REMEDY
Close cover completely; press start button longer.
254 Protective interlocking is defective
CAUSE
The protective switch is defective.
REMEDY
Replace protective switch.
258 Vacuum of the holding circuit is too low
CAUSE
Segments leaky; compressed air too low; vacuum circuit defective.
REMEDY
Check segments; adjust compressed air; replace vacuum circuit.
259 Axis command invalid at present
CAUSE
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
Fit new axis board.
260 Illegal bit combination in handshake byte
CAUSE
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
Fit new axis board.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
25
261 Component too large for opt. multiple measurement
CAUSE
The number of measurements determined by the vision system is greater than the maximum per-
mitted number.
REMEDY
Check the package form data.
262 Undefined axis command
CAUSE
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
Fit new axis board.
263 Undefined positioning type
CAUSE
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
Fit new axis board.
264 Limit switch actuated
CAUSE
Limit switch defective; axis miscounting and moving up against limit switch.
REMEDY
Clean scale; call Siemens Service.
265 Position outside travel range
CAUSE
Error in the local machine data.
REMEDY
Check positions.
266 Position contains an invalid character
CAUSE
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
Fit new axis board.
267 Position contains an invalid prefix character
CAUSE
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
Fit new axis board.