00191494-01 - 第26页
Error Messages Short Reference SIPLACE 80 S-15/F3/G 03/99 Issue Software Version SR.010.x x 24 251 PCB in conveyor, or conveyor running CAUSE ● PCB board on conveyo r during width adjustment. REMEDY ● Remove the PCB boar…
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
23
244 Center conveyor occupied
CAUSE
● When the function "Board to center conveyor" started there already was a PCB board on the cen-
ter conveyor; sensor defective.
When the belt speed was set the center conveyor was occupied.
REMEDY
● Remove the PCB board; fit new sensor.
245 Output conveyor occupied
CAUSE
● When the function "Board to output conveyor" started there already was a PCB board on the out-
put conveyor; sensor of output conveyor defective.
When the belt speed was set output conveyor was occupied.
REMEDY
● Remove the PCB board; fit new sensor.
246 BERO of left table side is not activated
CAUSE
● Bero is not covered.
REMEDY
● Check Bero.
247 Error in axis programming (left table side)
CAUSE
● Bero of the left table side defective; axis could not be moved.
REMEDY
● Check Bero; reboot.
248 BERO of left table side responding constantly
CAUSE
● Bero constantly covered.
REMEDY
● Check Bero.
249 Width adjustment at limit switch maximum width
CAUSE
● Width adjustment moved up to the limit switch; limit switch defective.
REMEDY
● Move width adjustment in other direction; fit new limit switch.
250 Width adjustment at limit switch minimum width
CAUSE
● Width adjustment moved up to the limit switch; limit switch defective.
REMEDY
● Move width adjustment in other direction; fit new limit switch.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
24
251 PCB in conveyor, or conveyor running
CAUSE
● PCB board on conveyor during width adjustment.
REMEDY
● Remove the PCB board.
252 Software relay for op.voltage defective
CAUSE
● Relay K5 defective.
REMEDY
● Replace relay K5.
253 No operating voltage
CAUSE
● Cover open; start button pressed too briefly.
REMEDY
● Close cover completely; press start button longer.
254 Protective interlocking is defective
CAUSE
● The protective switch is defective.
REMEDY
● Replace protective switch.
258 Vacuum of the holding circuit is too low
CAUSE
● Segments leaky; compressed air too low; vacuum circuit defective.
REMEDY
● Check segments; adjust compressed air; replace vacuum circuit.
259 Axis command invalid at present
CAUSE
● Axis board defective; local machine data incorrect; error should not occur.
REMEDY
● Fit new axis board.
260 Illegal bit combination in handshake byte
CAUSE
● Axis board defective; local machine data incorrect; error should not occur.
REMEDY
● Fit new axis board.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
25
261 Component too large for opt. multiple measurement
CAUSE
● The number of measurements determined by the vision system is greater than the maximum per-
mitted number.
REMEDY
● Check the package form data.
262 Undefined axis command
CAUSE
● Axis board defective; local machine data incorrect; error should not occur.
REMEDY
● Fit new axis board.
263 Undefined positioning type
CAUSE
● Axis board defective; local machine data incorrect; error should not occur.
REMEDY
● Fit new axis board.
264 Limit switch actuated
CAUSE
● Limit switch defective; axis miscounting and moving up against limit switch.
REMEDY
● Clean scale; call Siemens Service.
265 Position outside travel range
CAUSE
● Error in the local machine data.
REMEDY
● Check positions.
266 Position contains an invalid character
CAUSE
● Axis board defective; local machine data incorrect; error should not occur.
REMEDY
● Fit new axis board.
267 Position contains an invalid prefix character
CAUSE
● Axis board defective; local machine data incorrect; error should not occur.
REMEDY
● Fit new axis board.