Short Reference SIPLACE 80 S-15/F3/G Error Messages 03/99 Issue Software Version SR.010.x x 25 261 Component too large for opt. multiple measurement CAUSE ● The number of measurements determined by the vision system is g…

100%1 / 124
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
24
251 PCB in conveyor, or conveyor running
CAUSE
PCB board on conveyor during width adjustment.
REMEDY
Remove the PCB board.
252 Software relay for op.voltage defective
CAUSE
Relay K5 defective.
REMEDY
Replace relay K5.
253 No operating voltage
CAUSE
Cover open; start button pressed too briefly.
REMEDY
Close cover completely; press start button longer.
254 Protective interlocking is defective
CAUSE
The protective switch is defective.
REMEDY
Replace protective switch.
258 Vacuum of the holding circuit is too low
CAUSE
Segments leaky; compressed air too low; vacuum circuit defective.
REMEDY
Check segments; adjust compressed air; replace vacuum circuit.
259 Axis command invalid at present
CAUSE
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
Fit new axis board.
260 Illegal bit combination in handshake byte
CAUSE
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
Fit new axis board.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
25
261 Component too large for opt. multiple measurement
CAUSE
The number of measurements determined by the vision system is greater than the maximum per-
mitted number.
REMEDY
Check the package form data.
262 Undefined axis command
CAUSE
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
Fit new axis board.
263 Undefined positioning type
CAUSE
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
Fit new axis board.
264 Limit switch actuated
CAUSE
Limit switch defective; axis miscounting and moving up against limit switch.
REMEDY
Clean scale; call Siemens Service.
265 Position outside travel range
CAUSE
Error in the local machine data.
REMEDY
Check positions.
266 Position contains an invalid character
CAUSE
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
Fit new axis board.
267 Position contains an invalid prefix character
CAUSE
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
Fit new axis board.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
26
268 Undefined reference point type
CAUSE
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
Fit new axis board.
269 Acceleration/deceleration too great
CAUSE
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
Fit new axis board.
270 PCB interrupted due to EMERGENCY STOP
CAUSE
The guard was opened or the EMERGENCY STOP button pressed while placement was in pro-
gress.
REMEDY
Before opening the guard press the STOP switch and wait until the machine stops.
271 Check sum error of coplanarity
CAUSE
Error in the command to the coplanarity.
REMEDY
Repeat measurement; check supply voltage; jumper check.
272 Vision system not providing measure result
CAUSE
No component at the nozzle; component outside tolerance; not enough image information to pro-
vide measurement result.
REMEDY
Optimize pick-up; check charge (component) .
275 VS: Unknown request
CAUSE
Incorrect ICOS software version.
REMEDY
Check eproms and replace if necessary.
276 VS: Data not correct during request
CAUSE
Incorrect camera number in IDEAL.MA; obsolete ICOS software version.
REMEDY
Correct the machine data (IDEAL.MA); check eproms and replace if necessary.