Short Reference SIPLACE 80 S-15/F3/G Error Messages 03/99 Issue Software Version SR.010.x x 25 261 Component too large for opt. multiple measurement CAUSE ● The number of measurements determined by the vision system is g…
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
24
251 PCB in conveyor, or conveyor running
CAUSE
● PCB board on conveyor during width adjustment.
REMEDY
● Remove the PCB board.
252 Software relay for op.voltage defective
CAUSE
● Relay K5 defective.
REMEDY
● Replace relay K5.
253 No operating voltage
CAUSE
● Cover open; start button pressed too briefly.
REMEDY
● Close cover completely; press start button longer.
254 Protective interlocking is defective
CAUSE
● The protective switch is defective.
REMEDY
● Replace protective switch.
258 Vacuum of the holding circuit is too low
CAUSE
● Segments leaky; compressed air too low; vacuum circuit defective.
REMEDY
● Check segments; adjust compressed air; replace vacuum circuit.
259 Axis command invalid at present
CAUSE
● Axis board defective; local machine data incorrect; error should not occur.
REMEDY
● Fit new axis board.
260 Illegal bit combination in handshake byte
CAUSE
● Axis board defective; local machine data incorrect; error should not occur.
REMEDY
● Fit new axis board.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
25
261 Component too large for opt. multiple measurement
CAUSE
● The number of measurements determined by the vision system is greater than the maximum per-
mitted number.
REMEDY
● Check the package form data.
262 Undefined axis command
CAUSE
● Axis board defective; local machine data incorrect; error should not occur.
REMEDY
● Fit new axis board.
263 Undefined positioning type
CAUSE
● Axis board defective; local machine data incorrect; error should not occur.
REMEDY
● Fit new axis board.
264 Limit switch actuated
CAUSE
● Limit switch defective; axis miscounting and moving up against limit switch.
REMEDY
● Clean scale; call Siemens Service.
265 Position outside travel range
CAUSE
● Error in the local machine data.
REMEDY
● Check positions.
266 Position contains an invalid character
CAUSE
● Axis board defective; local machine data incorrect; error should not occur.
REMEDY
● Fit new axis board.
267 Position contains an invalid prefix character
CAUSE
● Axis board defective; local machine data incorrect; error should not occur.
REMEDY
● Fit new axis board.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
26
268 Undefined reference point type
CAUSE
● Axis board defective; local machine data incorrect; error should not occur.
REMEDY
● Fit new axis board.
269 Acceleration/deceleration too great
CAUSE
● Axis board defective; local machine data incorrect; error should not occur.
REMEDY
● Fit new axis board.
270 PCB interrupted due to EMERGENCY STOP
CAUSE
● The guard was opened or the EMERGENCY STOP button pressed while placement was in pro-
gress.
REMEDY
● Before opening the guard press the STOP switch and wait until the machine stops.
271 Check sum error of coplanarity
CAUSE
● Error in the command to the coplanarity.
REMEDY
● Repeat measurement; check supply voltage; jumper check.
272 Vision system not providing measure result
CAUSE
● No component at the nozzle; component outside tolerance; not enough image information to pro-
vide measurement result.
REMEDY
● Optimize pick-up; check charge (component) .
275 VS: Unknown request
CAUSE
● Incorrect ICOS software version.
REMEDY
● Check eproms and replace if necessary.
276 VS: Data not correct during request
CAUSE
● Incorrect camera number in IDEAL.MA; obsolete ICOS software version.
REMEDY
● Correct the machine data (IDEAL.MA); check eproms and replace if necessary.