Error Messages Short Reference SIPLACE 80 S-15/F3/G 03/99 Issue Software Version SR.010.x x 28 284 VS: A request is now being p rocessed CAUSE ● A request is being proc essed in the vision system. REMEDY ● If this error …
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
27
277 VS: Check sum error during data transmission
CAUSE
● Communications error
REMEDY
● If the error reoccurs with further attempts, first reset MVS, then station computer.
278 VS: Reference No. unknown, model not found
CAUSE
● The station refers to a package form or fiducial description which is not loaded in MVS/M10000.
REMEDY
● Load fiducials/package form description from vision system; check camera codes (IDEAL.MA/
REAL.MA).
279 VS: Incorrect parameters during request
CAUSE
● Incorrect camera number in IDEAL.MA; obsolete ICOS software version; FOV (field of view) data
in REAL.MA have too great a value.
REMEDY
● Correct the machine data (IDEAL.MA and REAL.MA); check eproms and replace if necessary.
280 VS: Not enough memory for a window definition
CAUSE
● Memory problems in the ICOS.
REMEDY
● Reset ICOS.
281 VS: Not enough memory for a definition
CAUSE
● ICOS cannot accept any further model descriptions.
REMEDY
● Reset ICOS and reload.
282 VS: Not enough memory for image
CAUSE
● Memory location problems in the ICOS.
REMEDY
● Reset ICOS.
283 Incorrect Eprom version in MVS
CAUSE
● The EPROM version in the MVS cannot be used with the station computer software. (Version dis-
played in the vision menu).
REMEDY
● Replace the EPROM in the MVS.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
28
284 VS: A request is now being processed
CAUSE
● A request is being processed in the vision system.
REMEDY
● If this error still occurs after numerous attempts, reset ICOS.
285 VS: Request cannot be finished and is being aborted
CAUSE
● The station refers to a package form or fiducial description which is not loaded in MVS/M10000.
REMEDY
● Load fiducials/package form description from vision system; check camera codes (IDEAL.MA/
REAL.MA).
286 VS: Hardware error in vision system (FATAL ERROR)
CAUSE
● Hardware error
REMEDY
● If this error still occurs after numerous attempts, reset ICOS.
287 Coplanarity has received a hardware break
CAUSE
● A hardware break was sent to the coplanarity module.
REMEDY
● Hardware error: check coplanarity module; check M18; check supply voltage of the coplanarity
module.
288 Telegram to coplanarity has no STX
CAUSE
● The first character sent to the coplanarity module is lost.
REMEDY
● Check supply voltage; check jumper; repeat measurement.
292 Communication to vision system defective (Error code -11)
CAUSE
● System error
REMEDY
● Reset system.
293 Communication to vision system defective (Error code -10)
CAUSE
● System error
REMEDY
● Reset system.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
29
294 Communication to vision system defective (Error code -9)
CAUSE
● System error
REMEDY
● Reset system.
295 Communication to vision system defective (Error code -8)
CAUSE
● System error
REMEDY
● Reset system.
296 Communication to vision system defective (Error code -7)
CAUSE
● System error
REMEDY
● Reset system.
297 Communication to vision system defective (Error code -6)
CAUSE
● System error
REMEDY
● Reset system.
298 Communication to vision system defective (Error code -5)
CAUSE
● System error
REMEDY
● Reset system.
299 Communication to vision system defective (Error code -4)
CAUSE
● System error
REMEDY
● Reset system.
300 Communication to vision system defective (Error code -3)
CAUSE
● Timeout during request to vision system (MVS / M10000).
REMEDY
● Reset vision system; at M10000 check V24 connection between MC and M10000.