00191494-01 - 第35页
Short Reference SIPLACE 80 S-15/F3/G Error Messages 03/99 Issue Software Version SR.010.x x 33 329 Measured value outside tol. (Error code 1FH) CAUSE ● Error during course of measure ment in the tester. REMEDY ● If occur…
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
32
321 Undefined error number from CRDL (Error code 17H)
CAUSE
● Hardware error at tester.
REMEDY
● Reset station, if occurs repeatedly and electrical testing is not possible, replace tester.
322 CRDL internal error (Error code 18H)
CAUSE
● Hardware error at tester.
REMEDY
● Reset station, if occurs repeatedly and electrical testing is not possible, replace tester.
323 Still no compensation values in CRDL (Error code 19H)
CAUSE
● Compensation not carried out.
REMEDY
● Carry out compensation with single functions.
325 Measure ranges exceeded (Error code 1BH)
CAUSE
● Setpoint specified is incorrect; incorrect component at the nozzle; mismeasurement (jaws dirty)
REMEDY
● Check data record for CRDL test in the component description in the line computer and correct if
necessary; check components; clean jaws.
326 Measured value outside tol. (Error code 1CH)
CAUSE
● Error during course of measurement in the tester.
REMEDY
● If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
327 Measured value outside tol. (Error code 1DH)
CAUSE
● Error during course of measurement in the tester.
REMEDY
● If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
328 Measured value outside tol. (Error code 1EH)
CAUSE
● Error during course of measurement in the tester.
REMEDY
● If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
33
329 Measured value outside tol. (Error code 1FH)
CAUSE
● Error during course of measurement in the tester.
REMEDY
● If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
330 Measured value outside tol. (Error code 20H)
CAUSE
● Error during course of measurement in the tester.
REMEDY
● If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
331 Measured value outside tol. (Error code 21H)
CAUSE
● Error during course of measurement in the tester.
REMEDY
● If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
332 Measured value outside tol. (Error code 22H)
CAUSE
● Error during course of measurement in the tester.
REMEDY
● If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
333 Phase error during CRDL measurement (Error code 23H)
CAUSE
● Incorrect component part at the nozzle; angle of the phase shift outside tolerance.
REMEDY
● Check component supply, set-up.
334 Measured value outside tol. (Error code 24H)
CAUSE
● Error during course of measurement in the tester.
REMEDY
● If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
34
335 Measured value outside tol. (Error code 25H)
CAUSE
● Error during course of measurement in the tester.
REMEDY
● If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
336 Measured value outside tol. (Error code 26H)
CAUSE
● Error during course of measurement in the tester.
REMEDY
● If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
337 Measured value outside tol. (Error code 27H)
CAUSE
● Error during course of measurement in the tester.
REMEDY
● If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
338 Measured value outside tol. (Error code 28H)
CAUSE
● Error during course of measurement in the tester.
REMEDY
● If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
339 Measured value outside tol. (Error code 29H)
CAUSE
● Component incorrect.
REMEDY
● Check set-up.
340 Wrong diode polarity, check feeder (2AH)
CAUSE
● Diode positioned incorrectly polarized between the measuring jaws.
REMEDY
●
341 Tantalum capacitor pol. not detected (2BH)
CAUSE
● Component incorrect.
REMEDY
● Check set-up.