00191494-01 - 第36页

Error Messages Short Reference SIPLACE 80 S-15/F3/G 03/99 Issue Software Version SR.010.x x 34 335 Measured value outside tol. (Error code 25H) CAUSE ● Error during course of m easurement in the tester. REMEDY ● If occur…

100%1 / 124
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
33
329 Measured value outside tol. (Error code 1FH)
CAUSE
Error during course of measurement in the tester.
REMEDY
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
330 Measured value outside tol. (Error code 20H)
CAUSE
Error during course of measurement in the tester.
REMEDY
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
331 Measured value outside tol. (Error code 21H)
CAUSE
Error during course of measurement in the tester.
REMEDY
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
332 Measured value outside tol. (Error code 22H)
CAUSE
Error during course of measurement in the tester.
REMEDY
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
333 Phase error during CRDL measurement (Error code 23H)
CAUSE
Incorrect component part at the nozzle; angle of the phase shift outside tolerance.
REMEDY
Check component supply, set-up.
334 Measured value outside tol. (Error code 24H)
CAUSE
Error during course of measurement in the tester.
REMEDY
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
34
335 Measured value outside tol. (Error code 25H)
CAUSE
Error during course of measurement in the tester.
REMEDY
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
336 Measured value outside tol. (Error code 26H)
CAUSE
Error during course of measurement in the tester.
REMEDY
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
337 Measured value outside tol. (Error code 27H)
CAUSE
Error during course of measurement in the tester.
REMEDY
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
338 Measured value outside tol. (Error code 28H)
CAUSE
Error during course of measurement in the tester.
REMEDY
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
339 Measured value outside tol. (Error code 29H)
CAUSE
Component incorrect.
REMEDY
Check set-up.
340 Wrong diode polarity, check feeder (2AH)
CAUSE
Diode positioned incorrectly polarized between the measuring jaws.
REMEDY
341 Tantalum capacitor pol. not detected (2BH)
CAUSE
Component incorrect.
REMEDY
Check set-up.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
35
342 Wrong tantal C pol., check feeder (2CH)
CAUSE
Capacitor positioned incorrectly polarized between the measuring jaws.
REMEDY
Not necessary since positioning corrected automatically.
343 Measured value outside tol. (Error code 2DH)
CAUSE
Error during course of measurement in the tester.
REMEDY
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
344 Measured value outside tol. (Error code 2EH)
CAUSE
Error during course of measurement in the tester.
REMEDY
If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
345 Calibration value is out of range (Error code 2FH)
CAUSE
Error during the course of calibration in the tester.
REMEDY
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
346 Calibration value is out of range (Error code 30H)
CAUSE
Error during the course of calibration in the tester.
REMEDY
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
347 Calibration value is out of range (Error code 31H)
CAUSE
Error during the course of calibration in the tester.
REMEDY
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
348 Calibration value is out of range (Error code 32H)
CAUSE
Error during the course of calibration in the tester.
REMEDY
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.