00191494-01 - 第37页
Short Reference SIPLACE 80 S-15/F3/G Error Messages 03/99 Issue Software Version SR.010.x x 35 342 Wrong tantal C pol., check feeder (2CH) CAUSE ● Capacitor positioned incorrect ly polarized between the me asuring jaws. …
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
34
335 Measured value outside tol. (Error code 25H)
CAUSE
● Error during course of measurement in the tester.
REMEDY
● If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
336 Measured value outside tol. (Error code 26H)
CAUSE
● Error during course of measurement in the tester.
REMEDY
● If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
337 Measured value outside tol. (Error code 27H)
CAUSE
● Error during course of measurement in the tester.
REMEDY
● If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
338 Measured value outside tol. (Error code 28H)
CAUSE
● Error during course of measurement in the tester.
REMEDY
● If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
339 Measured value outside tol. (Error code 29H)
CAUSE
● Component incorrect.
REMEDY
● Check set-up.
340 Wrong diode polarity, check feeder (2AH)
CAUSE
● Diode positioned incorrectly polarized between the measuring jaws.
REMEDY
●
341 Tantalum capacitor pol. not detected (2BH)
CAUSE
● Component incorrect.
REMEDY
● Check set-up.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
35
342 Wrong tantal C pol., check feeder (2CH)
CAUSE
● Capacitor positioned incorrectly polarized between the measuring jaws.
REMEDY
● Not necessary since positioning corrected automatically.
343 Measured value outside tol. (Error code 2DH)
CAUSE
● Error during course of measurement in the tester.
REMEDY
● If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
344 Measured value outside tol. (Error code 2EH)
CAUSE
● Error during course of measurement in the tester.
REMEDY
● If occurs repeatedly and electrical testing is not possible, first of all reset station; if this is not suc-
cessful, replace tester.
345 Calibration value is out of range (Error code 2FH)
CAUSE
● Error during the course of calibration in the tester.
REMEDY
● If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
346 Calibration value is out of range (Error code 30H)
CAUSE
● Error during the course of calibration in the tester.
REMEDY
● If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
347 Calibration value is out of range (Error code 31H)
CAUSE
● Error during the course of calibration in the tester.
REMEDY
● If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
348 Calibration value is out of range (Error code 32H)
CAUSE
● Error during the course of calibration in the tester.
REMEDY
● If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
36
349 Calibration value is out of range (Error code 33H)
CAUSE
● Error during the course of calibration in the tester.
REMEDY
● If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
350 Calibration value is out of range (Error code 34H)
CAUSE
● Error during the course of calibration in the tester.
REMEDY
● If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
351 Calibration value is out of range (Error code 35H)
CAUSE
● Error during the course of calibration in the tester.
REMEDY
● If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
352 Calibration value is out of range (Error code 36H)
CAUSE
● Error during the course of calibration in the tester.
REMEDY
● If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
353 Calibration value is out of range (Error code 37H)
CAUSE
● Error during the course of calibration in the tester.
REMEDY
● If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
354 Calibration value is out of range (Error code 38H)
CAUSE
● Error during the course of calibration in the tester.
REMEDY
● If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
355 Calibration value is out of range (Error code 39H)
CAUSE
● Error during the course of calibration in the tester.
REMEDY
● If electrical measuring is not possible, reset station; if resetting does not work, replace tester.