Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
42
390 Coplan.: Component not loaded
CAUSE
Attempt to measure a component for which no component description was sent to the coplanarity
module.
REMEDY
Check and respecify cluster, set-up and package form data.
391 Coplan.: Row number invalid
CAUSE
Package form description erroneous; software error.
REMEDY
Check and respecify package form description; inform Siemens Service.
392 Coplan.: Row number will not be processed
CAUSE
Package form description erroneous; software error.
REMEDY
Check and respecify package form description; inform Siemens Service.
393 Number of pins on component not correct
CAUSE
Bent / missing pins; erroneous package form description
REMEDY
Check components charge check; check package form description in the package form editor.
394 Orthogonality error during component meas.
CAUSE
Incorrect or deformed component.
REMEDY
Check components charge check.
395 Dualport RAM of CRDL defective
CAUSE
Hardware error in the tester.
REMEDY
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
396 Check sum error in CRDL measurement
CAUSE
Transmission error during transmission of machine controller with tester.
REMEDY
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
43
397 Check sum error in communication with table
CAUSE
Transmission error during transmission of machine controller with component table.
REMEDY
If error keeps recurring, reset station; if resetting does not work, replace component table.
398 Coplan.: Row not available
CAUSE
Package form description erroneous; software error.
REMEDY
Check and respecify package form description; inform Siemens Service.
399 Program loss of table or trolley control
CAUSE
Battery reserve in the component table is not working.
REMEDY
Fit new battery to component table.
400 RAM of trolley control defective
CAUSE
Hardware error in the component table
REMEDY
If error keeps recurring, reset station; if resetting does not work, replace component table.
401 New nozzle configuration is required
CAUSE
New cluster with different nozzle configuration
REMEDY
If no nozzle changer is present, apply new nozzle configuration manually to placement head.
402 Pulse is not okay
CAUSE
Connection of pulse output to pulse input defective.
REMEDY
Check pulse output and pulse input
403 Coplan.: Too many pins measured
CAUSE
Measurement erroneous or incorrect component.
REMEDY
Repeat measurement.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
44
404 Fault during vacuum measuring in reject position
CAUSE
Nozzle worn.
REMEDY
Fit new nozzle.
405 Fault during vacuum measuring in reject position
CAUSE
Proximity switch defective; component jammed between screwdriver and segment;
motor of the screwdriver defective.
REMEDY
Replace proximity switch, adjust sensing distance; remove component; check toothing for
damage; replace motor with hub, carry out calibration on the motor control board.
406 Axis does not find the correct zero pulse
CAUSE
Measurement head incorrectly set
REMEDY
Check zero pulse at the measurement head (moving scale) of the longitudinal measurement
system. Adjust or replace measurement head.
407 Communication with table disturbed
CAUSE
Timeout during request to the component table controller.
REMEDY
Check cabling.
408 Table has received unknown command
CAUSE
Obsolete TISCH.HEX file.
REMEDY
Update TISCH.HEX file.
410 Telegram to coplanarity too long
CAUSE
Package form description of the component includes too much information.
REMEDY
Check and respecify package form data; the package form is too large and cannot be processed.
423 Position: Evaluation not possible
CAUSE
Component is not positioned properly at the nozzle, or is missing; optical image inadequate.
REMEDY
Change the illumination values and / or the LUT.