00191494-01 - 第48页
Error Messages Short Reference SIPLACE 80 S-15/F3/G 03/99 Issue Software Version SR.010.x x 46 431 Colinearity: no result CAUSE ● Due to a preceding erro r no result is issued by the vision system. REMEDY ● See preceding…
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
45
424 Dimension: Evaluation not possible
CAUSE
● No component at the nozzle; component outside tolerance; not enough image information to pro-
vide measurement result.
REMEDY
● Optimize pick-up; check charge (component).
425 No. of pins: Evaluation not possible
CAUSE
● No component at the nozzle; component outside tolerance; not enough image information to pro-
vide measurement result.
REMEDY
● Optimize pick-up; check charge (component).
426 Colinearity: Evaluation not possible
CAUSE
● No component at the nozzle; component outside tolerance; not enough image information to pro-
vide measurement result.
REMEDY
● Optimize pick-up; check charge (component).
427 Spacing: Evaluation not possible
CAUSE
● No component at the nozzle; component outside tolerance; not enough image information to pro-
vide measurement result.
REMEDY
● Optimize pick-up; check charge (component).
428 Position: no result
CAUSE
● Due to a preceding error no result is issued by the vision system.
REMEDY
● See preceding error.
429 Dimension: no result
CAUSE
● Due to a preceding error no result is issued by the vision system.
REMEDY
● See preceding error.
430 No. of pins: no result
CAUSE
● Due to a preceding error no result is issued by the vision system.
REMEDY
● See preceding error.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
46
431 Colinearity: no result
CAUSE
● Due to a preceding error no result is issued by the vision system.
REMEDY
● See preceding error.
432 Spacing: no result
CAUSE
● Due to a preceding error no result is issued by the vision system.
REMEDY
● See preceding error.
433 Position: Component outside of search area
CAUSE
● Component was not picked up correctly.
REMEDY
● Check component description and pick-up position.
434 Dimension: Comp. outside of search area
CAUSE
● Component was not picked up correctly.
REMEDY
● Check component description and pick-up position.
435 No. of pins: Comp. outside of search area
CAUSE
● Component was not picked up correctly.
REMEDY
● Check component description and pick-up position.
436 Colinearity: Cmp. outside of search area
CAUSE
● Component was not picked up correctly.
REMEDY
● Check component description and pick-up position.
437 Spacing: Component outside of search area
CAUSE
● Component was not picked up correctly.
REMEDY
● Check component description and pick-up position.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
47
443 Coplan.: Measuring data buffer is full
CAUSE
● Mismeasurement: component out of focus or measurement interrupted by EMERGENCY STOP.
REMEDY
● Repeat measurement; correct focus; do not interrupt with EMERGENCY STOP.
447 Z-axis at IC head cannot be moved upwards
CAUSE
● When the start button is pressed the Z-axis of the IC head is at bottom and cannot be moved
upwards.
REMEDY
● Move Z-axis upwards manually; check Z-axis IC head.
449 IC head Z-axis does not reach placement/pick-up position
CAUSE
Z-axis of the IC head stiff; jamming of the IC head not corrected, position cannot be reached.
REMEDY
● Inform Siemens Service; inspect the jamming; check minimum and maximum travel range.
450 IC head Z-axis does not reach 0 position
CAUSE
● Z-axis of the IC head stiff; jamming of the IC head not corrected; erroneous zero point correction.
REMEDY
● Inform Siemens Service; inspect the jamming; change zero point correction.
451 IC head sensor for Z-axis does not react
CAUSE
● Top Bero of the Z-axis of the IC head defective; top Bero of the Z-axis of the IC head incorrectly
aligned;
erroneous zero point correction.
REMEDY
● Check input top Bero (input is always 0); realign top Bero of the Z-axis of the IC head; change
zero point correction.
452 IC head sensor for Z-axis is not released at top
CAUSE
● Top Bero of the Z-axis of the IC head defective.
REMEDY
● Check input top Bero (input is always 1).