Error Messages Short Reference SIPLACE 80 S-15/F3/G 03/99 Issue Software Version SR.010.x x 48 453 Component could not be place d CAUSE ● After placement by the IC head the component is still at the nozzle. REMEDY ● V ac…
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
47
443 Coplan.: Measuring data buffer is full
CAUSE
● Mismeasurement: component out of focus or measurement interrupted by EMERGENCY STOP.
REMEDY
● Repeat measurement; correct focus; do not interrupt with EMERGENCY STOP.
447 Z-axis at IC head cannot be moved upwards
CAUSE
● When the start button is pressed the Z-axis of the IC head is at bottom and cannot be moved
upwards.
REMEDY
● Move Z-axis upwards manually; check Z-axis IC head.
449 IC head Z-axis does not reach placement/pick-up position
CAUSE
Z-axis of the IC head stiff; jamming of the IC head not corrected, position cannot be reached.
REMEDY
● Inform Siemens Service; inspect the jamming; check minimum and maximum travel range.
450 IC head Z-axis does not reach 0 position
CAUSE
● Z-axis of the IC head stiff; jamming of the IC head not corrected; erroneous zero point correction.
REMEDY
● Inform Siemens Service; inspect the jamming; change zero point correction.
451 IC head sensor for Z-axis does not react
CAUSE
● Top Bero of the Z-axis of the IC head defective; top Bero of the Z-axis of the IC head incorrectly
aligned;
erroneous zero point correction.
REMEDY
● Check input top Bero (input is always 0); realign top Bero of the Z-axis of the IC head; change
zero point correction.
452 IC head sensor for Z-axis is not released at top
CAUSE
● Top Bero of the Z-axis of the IC head defective.
REMEDY
● Check input top Bero (input is always 1).
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
48
453 Component could not be placed
CAUSE
● After placement by the IC head the component is still at the nozzle.
REMEDY
● Vacuum circuit defective; forced air or vacuum cannot be switched off.
454 Component could not be placed. Warning!
CAUSE
● The component could be recognized as placed by the IC head only after the second measure-
ment.
REMEDY
● Check vacuum circuit; check forced air and vacuum of the IC head.
455 Component not on nozzle during placement
CAUSE
● After placement by the IC head the component is still at the nozzle.
REMEDY
● Vacuum circuit defective; forced air or vacuum cannot be switched off.
456 Component not on nozzle during placement. Warning!
CAUSE
● The component could be recognized as placed by the IC head only after the second measure-
ment.
REMEDY
● Check vacuum circuit; check forced air and vacuum of the IC head.
459 Coplan.: Memory for group description full
CAUSE
● In the set-up there are too many components with coplanarity measurement.
REMEDY
● Reduce set-up.
460 Coplan.: Memory for package form description full
CAUSE
● In the set-up there are too many components with coplanarity measurement.
REMEDY
● Reduce set-up.
461 Programmed position of D-axis outside of travel range
CAUSE
● Should not occur.
REMEDY
● Inform Siemens Service.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
49
462 Programmed position of Z-axis outside of travel range
CAUSE
● Head height, nozzle length erroneous.
REMEDY
● Correct head height, nozzle length.
463 IC head D-axis does not reach desired position
CAUSE
● Motor defective; clamping actuated.
REMEDY
● Fit new motor; release clamping and check.
464 IC head Z-axis does not reach desired position
CAUSE
● Motor defective; Z-axis jamming; clamping actuated.
REMEDY
● Fit new motor; check Z-axis; release clamping and check.
465 IC head D-axis disabled
CAUSE
● D-axis switched off at the axis controller switch.
REMEDY
● Switch on D-axis at the axis controller.
466 IC head Z-axis disabled
CAUSE
● Z-axis switched off at the axis controller switch.
REMEDY
● Switch on Z-axis at the axis controller.
467 Gantry distance insufficient. Protective system reacted
CAUSE
● Gantries have been moved too close together.
REMEDY
● Switch machine off and back on.
468 Component outside of positional tolerance
CAUSE
● Pick-up not accurate enough; positional tolerances entered in the package form editor are too
small.
REMEDY
● Optimize pick-up; raise positional tolerances in the package form editor.