Short Reference SIPLACE 80 S-15/F3/G Error Messages 03/99 Issue Software Version SR.010.x x 51 476 IC head vacuum of pick-up circle n ot in valid range CAUSE ● Nozzle dirty; vacuum cannot be switched on; permissible vacu…

100%1 / 124
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
50
469 Component outside of positional tolerance
CAUSE
Pick-up not accurate enough; positional tolerances entered in the package form editor are too
small.
REMEDY
Optimize pick-up; raise positional tolerances in the package form editor.
470 Component length outside tolerance
CAUSE
Incorrect component length; tolerances defined are too small.
REMEDY
Raise tolerance; check component description in the package form editor.
471 Component width outside tolerance
CAUSE
Incorrect component length; tolerances defined are too small.
REMEDY
Raise tolerance; check component description in the package form editor.
472 VS: Pointer to text table not initialized
CAUSE
Component is not in focus during coplanarity measurement.
REMEDY
Check the focussing during coplanarity measurement; check the IC head Z-axis clamping
473 Temporary drop in pressure
CAUSE
The compressed air failed during the placement process, the current PCB board is aborted.
REMEDY
Check compressed air feed; check compressed air sensor.
474 Second gantry in travel range
CAUSE
While teaching the fiducials (80S), the operator moved the gantries towards each other.
REMEDY
Move the second gantry out of the travel range of the first gantry.
475 Communication with wafflepack changer faulty
CAUSE
Interface line to the wafflepack changer defective or not correctly connected; power supply to the
wafflepack changer defective.
REMEDY
Check interface cable; check power supply.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
51
476 IC head vacuum of pick-up circle not in valid range
CAUSE
Nozzle dirty; vacuum cannot be switched on; permissible vacuum limit value for open nozzle erro-
neous.
REMEDY
Clean nozzle; check vacuum output and vacuum valve; correct vacuum limit value for open
nozzle.
477 Nozzle available on IC head
CAUSE
According to the software configuration there is already a nozzle at the head. This message
appears when an attempt is still made to start the pick-up procedure.
REMEDY
If there does not happen to be a nozzle at the head, set up the nozzle specified by the configura-
tion by hand.
478 Deviation position Z-axis at nozzle changer IC head
CAUSE
Z-axis has gone beyond or not reached its desired position (MA data); the Z-axis is jamming
the nozzle is already at the head at pick-up.
REMEDY
Check the x, y and z positions; make sure the axis can move freely.
479 Deviation rotation D-axis pick up nozzle IC head
CAUSE
The d axis is rotating with standstill check as far as the stop. If the actual position (angular posi-
tion at the stop) deviates from the desired position (MA data) by more than 15 degrees in either
the positive or the negative direction, this message will appear.
REMEDY
Remeasurement and inputting into MA data.
480 Deviation rotation D-axis return nozzle IC head
CAUSE
The d axis is rotating with standstill check as far as the stop. If the actual position (angular posi-
tion at the stop) deviates from the desired position (MA data) by more than 15 degrees in either
the positive or the negative direction, this message will appear.
REMEDY
Remeasurement and inputting into MA data.
481 Nozzle not available at nozzle changer IC head
CAUSE
A nozzle is being requested which is not in the nozzle changer.
REMEDY
If request by machine: check set-up.
If input by operator: correct incorrect input.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
52
482 Modify nozzle changer IC head
CAUSE
A new assignment in the nozzle changer IC head is being called for by the line computer.
REMEDY
Set up new assignment and acknowledge.
484 Coplan.: Division by zero
CAUSE
Placement level could not be determined.
REMEDY
Repeat measurement.
486 Coplan.: Component outside of measuring range
CAUSE
Component not in focus during coplanarity measurement.
REMEDY
Check focus of coplanarity; check clamping of Z-axis IC head.
487 Coplan.: One pin of component missing
CAUSE
Focusing of coplanarity measurement incorrect; component defective.
REMEDY
Check focusing; repeat measurement.
488 Coplan.: Measuring on one pin finished
CAUSE
Focusing of coplanarity measurement incorrect; component defective.
REMEDY
Check focus; repeat measurement.
489 Coplan.: Pin outside of coplan. position tolerance
CAUSE
Pin bent; component defective.
REMEDY
Repeat measurement with new component.
490 Coplan.: Placement level not found
CAUSE
Placement level could not be determined.
REMEDY
Repeat measurement.