00191494-01 - 第53页
Short Reference SIPLACE 80 S-15/F3/G Error Messages 03/99 Issue Software Version SR.010.x x 51 476 IC head vacuum of pick-up circle n ot in valid range CAUSE ● Nozzle dirty; vacuum cannot be switched on; permissible vacu…
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
50
469 Component outside of positional tolerance
CAUSE
● Pick-up not accurate enough; positional tolerances entered in the package form editor are too
small.
REMEDY
● Optimize pick-up; raise positional tolerances in the package form editor.
470 Component length outside tolerance
CAUSE
● Incorrect component length; tolerances defined are too small.
REMEDY
● Raise tolerance; check component description in the package form editor.
471 Component width outside tolerance
CAUSE
● Incorrect component length; tolerances defined are too small.
REMEDY
● Raise tolerance; check component description in the package form editor.
472 VS: Pointer to text table not initialized
CAUSE
● Component is not in focus during coplanarity measurement.
REMEDY
● Check the focussing during coplanarity measurement; check the IC head Z-axis clamping
473 Temporary drop in pressure
CAUSE
● The compressed air failed during the placement process, the current PCB board is aborted.
REMEDY
● Check compressed air feed; check compressed air sensor.
474 Second gantry in travel range
CAUSE
● While teaching the fiducials (80S), the operator moved the gantries towards each other.
REMEDY
● Move the second gantry out of the travel range of the first gantry.
475 Communication with wafflepack changer faulty
CAUSE
● Interface line to the wafflepack changer defective or not correctly connected; power supply to the
wafflepack changer defective.
REMEDY
● Check interface cable; check power supply.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
51
476 IC head vacuum of pick-up circle not in valid range
CAUSE
● Nozzle dirty; vacuum cannot be switched on; permissible vacuum limit value for open nozzle erro-
neous.
REMEDY
● Clean nozzle; check vacuum output and vacuum valve; correct vacuum limit value for open
nozzle.
477 Nozzle available on IC head
CAUSE
● According to the software configuration there is already a nozzle at the head. This message
appears when an attempt is still made to start the pick-up procedure.
REMEDY
● If there does not happen to be a nozzle at the head, set up the nozzle specified by the configura-
tion by hand.
478 Deviation position Z-axis at nozzle changer IC head
CAUSE
● Z-axis has gone beyond or not reached its desired position (MA data); the Z-axis is jamming
the nozzle is already at the head at pick-up.
REMEDY
● Check the x, y and z positions; make sure the axis can move freely.
479 Deviation rotation D-axis pick up nozzle IC head
CAUSE
● The d axis is rotating with standstill check as far as the stop. If the actual position (angular posi-
tion at the stop) deviates from the desired position (MA data) by more than 15 degrees in either
the positive or the negative direction, this message will appear.
REMEDY
● Remeasurement and inputting into MA data.
480 Deviation rotation D-axis return nozzle IC head
CAUSE
● The d axis is rotating with standstill check as far as the stop. If the actual position (angular posi-
tion at the stop) deviates from the desired position (MA data) by more than 15 degrees in either
the positive or the negative direction, this message will appear.
REMEDY
● Remeasurement and inputting into MA data.
481 Nozzle not available at nozzle changer IC head
CAUSE
● A nozzle is being requested which is not in the nozzle changer.
REMEDY
● If request by machine: check set-up.
If input by operator: correct incorrect input.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
52
482 Modify nozzle changer IC head
CAUSE
● A new assignment in the nozzle changer IC head is being called for by the line computer.
REMEDY
● Set up new assignment and acknowledge.
484 Coplan.: Division by zero
CAUSE
● Placement level could not be determined.
REMEDY
● Repeat measurement.
486 Coplan.: Component outside of measuring range
CAUSE
● Component not in focus during coplanarity measurement.
REMEDY
● Check focus of coplanarity; check clamping of Z-axis IC head.
487 Coplan.: One pin of component missing
CAUSE
● Focusing of coplanarity measurement incorrect; component defective.
REMEDY
● Check focusing; repeat measurement.
488 Coplan.: Measuring on one pin finished
CAUSE
● Focusing of coplanarity measurement incorrect; component defective.
REMEDY
● Check focus; repeat measurement.
489 Coplan.: Pin outside of coplan. position tolerance
CAUSE
● Pin bent; component defective.
REMEDY
● Repeat measurement with new component.
490 Coplan.: Placement level not found
CAUSE
● Placement level could not be determined.
REMEDY
● Repeat measurement.