00191494-01 - 第54页

Error Messages Short Reference SIPLACE 80 S-15/F3/G 03/99 Issue Software Version SR.010.x x 52 482 Modify nozzle changer IC hea d CAUSE ● A new assignment in th e nozzle changer IC head is being called for by the line co…

100%1 / 124
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
51
476 IC head vacuum of pick-up circle not in valid range
CAUSE
Nozzle dirty; vacuum cannot be switched on; permissible vacuum limit value for open nozzle erro-
neous.
REMEDY
Clean nozzle; check vacuum output and vacuum valve; correct vacuum limit value for open
nozzle.
477 Nozzle available on IC head
CAUSE
According to the software configuration there is already a nozzle at the head. This message
appears when an attempt is still made to start the pick-up procedure.
REMEDY
If there does not happen to be a nozzle at the head, set up the nozzle specified by the configura-
tion by hand.
478 Deviation position Z-axis at nozzle changer IC head
CAUSE
Z-axis has gone beyond or not reached its desired position (MA data); the Z-axis is jamming
the nozzle is already at the head at pick-up.
REMEDY
Check the x, y and z positions; make sure the axis can move freely.
479 Deviation rotation D-axis pick up nozzle IC head
CAUSE
The d axis is rotating with standstill check as far as the stop. If the actual position (angular posi-
tion at the stop) deviates from the desired position (MA data) by more than 15 degrees in either
the positive or the negative direction, this message will appear.
REMEDY
Remeasurement and inputting into MA data.
480 Deviation rotation D-axis return nozzle IC head
CAUSE
The d axis is rotating with standstill check as far as the stop. If the actual position (angular posi-
tion at the stop) deviates from the desired position (MA data) by more than 15 degrees in either
the positive or the negative direction, this message will appear.
REMEDY
Remeasurement and inputting into MA data.
481 Nozzle not available at nozzle changer IC head
CAUSE
A nozzle is being requested which is not in the nozzle changer.
REMEDY
If request by machine: check set-up.
If input by operator: correct incorrect input.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
52
482 Modify nozzle changer IC head
CAUSE
A new assignment in the nozzle changer IC head is being called for by the line computer.
REMEDY
Set up new assignment and acknowledge.
484 Coplan.: Division by zero
CAUSE
Placement level could not be determined.
REMEDY
Repeat measurement.
486 Coplan.: Component outside of measuring range
CAUSE
Component not in focus during coplanarity measurement.
REMEDY
Check focus of coplanarity; check clamping of Z-axis IC head.
487 Coplan.: One pin of component missing
CAUSE
Focusing of coplanarity measurement incorrect; component defective.
REMEDY
Check focusing; repeat measurement.
488 Coplan.: Measuring on one pin finished
CAUSE
Focusing of coplanarity measurement incorrect; component defective.
REMEDY
Check focus; repeat measurement.
489 Coplan.: Pin outside of coplan. position tolerance
CAUSE
Pin bent; component defective.
REMEDY
Repeat measurement with new component.
490 Coplan.: Placement level not found
CAUSE
Placement level could not be determined.
REMEDY
Repeat measurement.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
53
492 Coplanarity module defective; replace and boot
CAUSE
Internal error of the coplanarity module.
REMEDY
Inform Siemens Service.
493 Coplanarity module defective; replace and boot
CAUSE
Internal error of the coplanarity module.
REMEDY
Inform Siemens Service.
494 Coplanarity module defective; replace and boot
CAUSE
Internal error of the coplanarity module.
REMEDY
Inform Siemens Service.
495 Coplanarity module defective; replace and boot
CAUSE
Internal error of the coplanarity module.
REMEDY
Inform Siemens Service.
496 Coplanarity module defective; replace and boot
CAUSE
Internal error of the coplanarity module.
REMEDY
Inform Siemens Service.
497 Software error in coplanarity module; boot
CAUSE
Internal error of the coplanarity module.
REMEDY
Inform Siemens Service.
498 Coplan.: Command Quit sent
CAUSE
Software error
REMEDY
Inform Siemens Service.