00191494-01 - 第55页
Short Reference SIPLACE 80 S-15/F3/G Error Messages 03/99 Issue Software Version SR.010.x x 53 492 Coplanarity module defective; repl ace and boot CAUSE ● Internal error of the coplanari ty module. REMEDY ● Inform Siemen…
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
52
482 Modify nozzle changer IC head
CAUSE
● A new assignment in the nozzle changer IC head is being called for by the line computer.
REMEDY
● Set up new assignment and acknowledge.
484 Coplan.: Division by zero
CAUSE
● Placement level could not be determined.
REMEDY
● Repeat measurement.
486 Coplan.: Component outside of measuring range
CAUSE
● Component not in focus during coplanarity measurement.
REMEDY
● Check focus of coplanarity; check clamping of Z-axis IC head.
487 Coplan.: One pin of component missing
CAUSE
● Focusing of coplanarity measurement incorrect; component defective.
REMEDY
● Check focusing; repeat measurement.
488 Coplan.: Measuring on one pin finished
CAUSE
● Focusing of coplanarity measurement incorrect; component defective.
REMEDY
● Check focus; repeat measurement.
489 Coplan.: Pin outside of coplan. position tolerance
CAUSE
● Pin bent; component defective.
REMEDY
● Repeat measurement with new component.
490 Coplan.: Placement level not found
CAUSE
● Placement level could not be determined.
REMEDY
● Repeat measurement.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
53
492 Coplanarity module defective; replace and boot
CAUSE
● Internal error of the coplanarity module.
REMEDY
● Inform Siemens Service.
493 Coplanarity module defective; replace and boot
CAUSE
● Internal error of the coplanarity module.
REMEDY
● Inform Siemens Service.
494 Coplanarity module defective; replace and boot
CAUSE
● Internal error of the coplanarity module.
REMEDY
● Inform Siemens Service.
495 Coplanarity module defective; replace and boot
CAUSE
● Internal error of the coplanarity module.
REMEDY
● Inform Siemens Service.
496 Coplanarity module defective; replace and boot
CAUSE
● Internal error of the coplanarity module.
REMEDY
● Inform Siemens Service.
497 Software error in coplanarity module; boot
CAUSE
● Internal error of the coplanarity module.
REMEDY
● Inform Siemens Service.
498 Coplan.: Command Quit sent
CAUSE
● Software error
REMEDY
● Inform Siemens Service.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
54
499 Peak offset: Component outside of search area
CAUSE
● Component was not picked up correctly.
REMEDY
● Check component description and pick-up position.
500 Peak offset: Evaluation not possible
CAUSE
● No component at the nozzle; component outside tolerance; not enough image information to pro-
vide measurement result.
REMEDY
● Optimize pick-up; check charge (component).
501 Error in default branch
CAUSE
● The format of the measurement results from optical centering cannot be interpreted by the MC
software.
REMEDY
● Check sure that the MVS Eprom version is compatible with the station computer software.
502 MC has received wrong error number
CAUSE
● Software error: the error number lies outside the error range
REMEDY
● Notify Siemens Service.
503 Flatpack magazine is empty
CAUSE
● Last component of a flatpack magazine has been picked up.
REMEDY
● Change flatpack magazine.
504 Current limiter I
r.m.s
has reacted
CAUSE
● Servo is being subjected to limitation, axis jamming.
REMEDY
● Check mechanism for ease of running.
505 Error during RMOS System Call RECV
CAUSE
● Software error
REMEDY
● Reboot and inform Siemens Service.