00191494-01 - 第56页
Error Messages Short Reference SIPLACE 80 S-15/F3/G 03/99 Issue Software Version SR.010.x x 54 499 Peak offset: Component outsid e of search area CAUSE ● Component was not pic ked up correctly . REMEDY ● Check component …
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
53
492 Coplanarity module defective; replace and boot
CAUSE
● Internal error of the coplanarity module.
REMEDY
● Inform Siemens Service.
493 Coplanarity module defective; replace and boot
CAUSE
● Internal error of the coplanarity module.
REMEDY
● Inform Siemens Service.
494 Coplanarity module defective; replace and boot
CAUSE
● Internal error of the coplanarity module.
REMEDY
● Inform Siemens Service.
495 Coplanarity module defective; replace and boot
CAUSE
● Internal error of the coplanarity module.
REMEDY
● Inform Siemens Service.
496 Coplanarity module defective; replace and boot
CAUSE
● Internal error of the coplanarity module.
REMEDY
● Inform Siemens Service.
497 Software error in coplanarity module; boot
CAUSE
● Internal error of the coplanarity module.
REMEDY
● Inform Siemens Service.
498 Coplan.: Command Quit sent
CAUSE
● Software error
REMEDY
● Inform Siemens Service.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
54
499 Peak offset: Component outside of search area
CAUSE
● Component was not picked up correctly.
REMEDY
● Check component description and pick-up position.
500 Peak offset: Evaluation not possible
CAUSE
● No component at the nozzle; component outside tolerance; not enough image information to pro-
vide measurement result.
REMEDY
● Optimize pick-up; check charge (component).
501 Error in default branch
CAUSE
● The format of the measurement results from optical centering cannot be interpreted by the MC
software.
REMEDY
● Check sure that the MVS Eprom version is compatible with the station computer software.
502 MC has received wrong error number
CAUSE
● Software error: the error number lies outside the error range
REMEDY
● Notify Siemens Service.
503 Flatpack magazine is empty
CAUSE
● Last component of a flatpack magazine has been picked up.
REMEDY
● Change flatpack magazine.
504 Current limiter I
r.m.s
has reacted
CAUSE
● Servo is being subjected to limitation, axis jamming.
REMEDY
● Check mechanism for ease of running.
505 Error during RMOS System Call RECV
CAUSE
● Software error
REMEDY
● Reboot and inform Siemens Service.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
55
506 Error during RMOS System Call DALOC
CAUSE
● Software error
REMEDY
● Reboot and inform Siemens Service.
507 Error during RMOS System Call ALOC
CAUSE
● Software error
REMEDY
● Reboot and inform Siemens Service.
508 Error during RMOS System Call LOOK
CAUSE
● Software error
REMEDY
● Reboot and inform Siemens Service.
509 Error during RMOS System Call RIO
CAUSE
● Software error
REMEDY
● Reboot and inform Siemens Service.
510 Error during RMOS System Call CREATEDRIV
CAUSE
● Software error
REMEDY
● Reboot and inform Siemens Service.
511 Error during RMOS System Call MALLOC
CAUSE
● Software error
REMEDY
● Reboot and inform Siemens Service.
512 Incorrect value of state counter
CAUSE
● Software error
REMEDY
● Reboot