Short Reference SIPLACE 80 S-15/F3/G Error Messages 03/99 Issue Software Version SR.010.x x 55 506 Error during RMOS System Call DA LOC CAUSE ● Software error REMEDY ● Reboot and inform Siemens S ervice. 507 Error during…

100%1 / 124
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
54
499 Peak offset: Component outside of search area
CAUSE
Component was not picked up correctly.
REMEDY
Check component description and pick-up position.
500 Peak offset: Evaluation not possible
CAUSE
No component at the nozzle; component outside tolerance; not enough image information to pro-
vide measurement result.
REMEDY
Optimize pick-up; check charge (component).
501 Error in default branch
CAUSE
The format of the measurement results from optical centering cannot be interpreted by the MC
software.
REMEDY
Check sure that the MVS Eprom version is compatible with the station computer software.
502 MC has received wrong error number
CAUSE
Software error: the error number lies outside the error range
REMEDY
Notify Siemens Service.
503 Flatpack magazine is empty
CAUSE
Last component of a flatpack magazine has been picked up.
REMEDY
Change flatpack magazine.
504 Current limiter I
r.m.s
has reacted
CAUSE
Servo is being subjected to limitation, axis jamming.
REMEDY
Check mechanism for ease of running.
505 Error during RMOS System Call RECV
CAUSE
Software error
REMEDY
Reboot and inform Siemens Service.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
55
506 Error during RMOS System Call DALOC
CAUSE
Software error
REMEDY
Reboot and inform Siemens Service.
507 Error during RMOS System Call ALOC
CAUSE
Software error
REMEDY
Reboot and inform Siemens Service.
508 Error during RMOS System Call LOOK
CAUSE
Software error
REMEDY
Reboot and inform Siemens Service.
509 Error during RMOS System Call RIO
CAUSE
Software error
REMEDY
Reboot and inform Siemens Service.
510 Error during RMOS System Call CREATEDRIV
CAUSE
Software error
REMEDY
Reboot and inform Siemens Service.
511 Error during RMOS System Call MALLOC
CAUSE
Software error
REMEDY
Reboot and inform Siemens Service.
512 Incorrect value of state counter
CAUSE
Software error
REMEDY
Reboot
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
56
513 Unknown operating state message
CAUSE
Software error
REMEDY
Reboot
514 Illegal operating state
CAUSE
Software error
REMEDY
Reboot
515 SV: Unknown data code
CAUSE
Software error
REMEDY
Inform Siemens Service
516 SV: Incorrect data length
CAUSE
Software error
REMEDY
Inform Siemens Service
517 Software error: Answer from coplanarity too long
CAUSE
Software error: the answer from coplanarity exceeds the buffer length in the MC
REMEDY
Repeat the coplanarity measurement; notify Siemens Service.
518 SV: Unknown message code from other MC
CAUSE
Software error
REMEDY
Inform Siemens Service.
519 SV: Unknown message code from station computer
CAUSE
Software error
REMEDY
Inform Siemens Service.