00191494-01 - 第59页
Short Reference SIPLACE 80 S-15/F3/G Error Messages 03/99 Issue Software Version SR.010.x x 57 520 Unknown data code in MC1 during d ata exchange CAUSE ● Software error REMEDY ● If there are problems after thi s, reset s…
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
56
513 Unknown operating state message
CAUSE
● Software error
REMEDY
● Reboot
514 Illegal operating state
CAUSE
● Software error
REMEDY
● Reboot
515 SV: Unknown data code
CAUSE
● Software error
REMEDY
● Inform Siemens Service
516 SV: Incorrect data length
CAUSE
● Software error
REMEDY
● Inform Siemens Service
517 Software error: Answer from coplanarity too long
CAUSE
● Software error: the answer from coplanarity exceeds the buffer length in the MC
REMEDY
● Repeat the coplanarity measurement; notify Siemens Service.
518 SV: Unknown message code from other MC
CAUSE
● Software error
REMEDY
● Inform Siemens Service.
519 SV: Unknown message code from station computer
CAUSE
● Software error
REMEDY
● Inform Siemens Service.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
57
520 Unknown data code in MC1 during data exchange
CAUSE
● Software error
REMEDY
● If there are problems after this, reset station, inform Siemens Service.
521 Software error in SGL Functions
CAUSE
● Incorrect message to single function (Info1) operator error during transition to single function or
fatal error handling ( start button not pressed ).
REMEDY
● Possibly rebooting
522 Syntax error in command to component table
CAUSE
● Software error; interface cable reversed.
REMEDY
● Reboot; connect interface cable correctly.
523 Command not executed, component table not referred
CAUSE
● Power failure while component carriage moving.
REMEDY
● Check power supply and inform Siemens Service.
524 Command not executed, component table in refill position
CAUSE
● Software error
REMEDY
● Reboot
525 WPC: No tray available.
CAUSE
● Software error
REMEDY
● Reboot
526 WPC: Sent set-up contains errors.
CAUSE
● Software error
REMEDY
● Reboot
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
58
527 Feeder rail of bulk case feeder not installed
CAUSE
● The feeder rail is not installed on the bulk case feeder
REMEDY
● Install feeder rail on bulk case feeder
533 WPC: Data loss in component table (defective battery)
CAUSE
● Backup battery flat or defective; Controller A18 defective.
REMEDY
● Replace battery; fit new A18 and inform Siemens Service.
534 WPC: Fault in feed axis (servo or axis card).
CAUSE
● Axis board of the feed axis defective; servo of the feed axis defective.
REMEDY
● Fit new axis board or servo board and inform Siemens Service.
535 WPC: Feed axis at limit switch
CAUSE
● Feed axis at the limit switch; limit switch defective.
REMEDY
● Push feed axis away from limit switch; fit new limit switch.
536 WPC: Axis error of feed axis
CAUSE
● Undefined reference point or type of positioning; undefined axis command; position outside the
travel range.
REMEDY
● Reboot; inform Siemens Service.
537 WPC: Feed axis servo released.
CAUSE
● Servo disabled at the axis board.
REMEDY
● Switch servo back on at the axis board.
538 WPC: Error in jaw position
CAUSE
● At the zero point position the reference Bero of the feed axis is not actuated; incorrect zero point
correction; Bero defective.
REMEDY
● Correct zero point correction; replace Bero.