00191494-01 - 第64页
Error Messages Short Reference SIPLACE 80 S-15/F3/G 03/99 Issue Software Version SR.010.x x 62 560 Error during execution of SP nozzle head check CAUSE ● Error in program run In the menu "General errors" the fo…
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
61
553 Coplan.: Software error during system call RIO
CAUSE
● Communication with the coplanarity module has been interrupted
REMEDY
● Check the V-24 interface cable; check the jumper setting of the coplanarity module.
554 Communication between SR and MC interrupted
CAUSE
● Hardware fault in a module (M18, M34) or a wiring fault.
REMEDY
● Replace modules; check the wiring at the back of the control unit.
555 IC head nozzle changer option not set
CAUSE
● The nozzle-changer was called without this option being set in the line computer.
REMEDY
● Configure the nozzle-changer in the line computer.
556 Nozzle type not available
CAUSE
● During nozzle changing or pick-up a nozzle type was demanded which lies outside the valid
range.
REMEDY
● Check the cluster and set-up.
557 Nozzle type not in IC-head nozzle changer set-up
CAUSE
● The nozzle type required was not included in the nozzle-changer set-up
REMEDY
● Modify nozzle-changer set-up.
558 Error during MVS initialization via HS3L
CAUSE
● Wiring of HS3L interface faulty; MVS card not inserted correctly in control unit.
REMEDY
● Check HS3L wiring; check seating of the MVS card.
559 Data error in MC: optical centering indices incorrect
CAUSE
● The job data are inconsistent.
REMEDY
● Check the camera records in the REAL.MA file; check the job data (GF data) in the line computer.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
62
560 Error during execution of SP nozzle head check
CAUSE
● Error in program run
In the menu "General errors" the following applies to Info1:
Info1 = 1 Setting up not necessary
Info1 = 2 Magazine no. invalid
Info1 = 3 Segment no. invalid
Info1 = 4 Garage not found
REMEDY
● Notify Siemens Service.
561 Modify SP head nozzle-changer
CAUSE
● The corresponding nozzle type has not been set up in the nozzle-changer
REMEDY
● Modify nozzle-changer set-up in accordance with required specification and confirm in the menu
with the return key.
562 Error while loading GF geom. description data into MVS
CAUSE
● Camera records in real.ma are erroneous; old MVS Eprom version; GF description (line compu-
ter) erroneous; incorrect sensor system type input at line computer
REMEDY
● Check camera records (real.ma); check Eprom MVS version
563 Error while loading GF meas. conditions data into MVS
CAUSE
● Erroneous manipulation of measuring conditions (test vision system / component; “Rucksack” file
from line computer faulty (part of GF file which can be manipulated)
REMEDY
● Undo manipulation; delete “Rucksack” file in the line computer or assign new GF number
565 Error during loading of fiducials into MVS
CAUSE
● Fiducial data from the line computer or station computer disk are erroneous; incorrect MVS
Eprom version
REMEDY
● Delete fiducial data and teach them again; check MVS Eprom version
566 Error while loading fiducial centering param. into MVS
CAUSE
● Fiducial data from the line computer or station computer disk are erroneous; incorrect MVS
Eprom version
REMEDY
● Delete fiducial data and teach them again; check MVS Eprom version
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
63
567 Error while loading coplanarity data into module
CAUSE
● Coplanarity has been selected for BGAs; erroneous GF description in the line computer
REMEDY
● Deactivate coplanarity option; check GF description
568 Error while loading parameter pool into MVS
CAUSE
● Erroneous data in the SST.ma file; incorrect MVS Eprom version
REMEDY
● Check the SST.ma file; check the MVS Eprom version
569 Limited feeder position recognition
CAUSE
● Feeder fiducials are outside the travel range of the main axes
REMEDY
● Set feeder up for locations which lie within the travel range of the board camera
570 Nozzle not picked up from <magazine/garage>:
CAUSE
● Garage indicated of the magazine in question is already empty; x, y or z positions are not correct
(real.ma)
REMEDY
● Set magazine full; check the garage in question
571 Nozzle not returned to <magazine/garage>:
CAUSE
● Garage indicated of the magazine in question is already occupied; x, y or z positions are not cor-
rect (real.ma)
REMEDY
● Nozzle is discarded into rejects tray; check the garage in question
572 Nozzle type not available <type/for segment>:
CAUSE
● Nozzle type displayed has not been set up or the corresponding magazine is empty
REMEDY
● Fill magazine or insert by hand and confirm in the menu
573 Nozzle type not returnable <type/from segment>:
CAUSE
● Magazine displayed has not been set up for this nozzle type or the magazine is full
REMEDY
● Nozzle is discarded into the rejects tray