61
553 Coplan.: Software error during system call RIO
CAUSE
Communication with the coplanarity module has been interrupted
REMEDY
Check the V-24 interface cable; check the jumper setting of the coplanarity module.
554 Communication between SR and MC interrupted
CAUSE
Hardware fault in a module (M18, M34) or a wiring fault.
REMEDY
Replace modules; check the wiring at the back of the control unit.
555 IC head nozzle changer option not set
CAUSE
The nozzle-changer was called without this option being set in the line computer.
REMEDY
Configure the nozzle-changer in the line computer.
556 Nozzle type not available
CAUSE
During nozzle changing or pick-up a nozzle type was demanded which lies outside the valid
range.
REMEDY
Check the cluster and set-up.
557 Nozzle type not in IC-head nozzle changer set-up
CAUSE
The nozzle type required was not included in the nozzle-changer set-up
REMEDY
Modify nozzle-changer set-up.
558 Error during MVS initialization via HS3L
CAUSE
Wiring of HS3L interface faulty; MVS card not inserted correctly in control unit.
REMEDY
Check HS3L wiring; check seating of the MVS card.
559 Data error in MC: optical centering indices incorrect
CAUSE
The job data are inconsistent.
REMEDY
Check the camera records in the REAL.MA file; check the job data (GF data) in the line computer.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
62
560 Error during execution of SP nozzle head check
CAUSE
Error in program run
In the menu "General errors" the following applies to Info1:
Info1 = 1 Setting up not necessary
Info1 = 2 Magazine no. invalid
Info1 = 3 Segment no. invalid
Info1 = 4 Garage not found
REMEDY
Notify Siemens Service.
561 Modify SP head nozzle-changer
CAUSE
The corresponding nozzle type has not been set up in the nozzle-changer
REMEDY
Modify nozzle-changer set-up in accordance with required specification and confirm in the menu
with the return key.
562 Error while loading GF geom. description data into MVS
CAUSE
Camera records in real.ma are erroneous; old MVS Eprom version; GF description (line compu-
ter) erroneous; incorrect sensor system type input at line computer
REMEDY
Check camera records (real.ma); check Eprom MVS version
563 Error while loading GF meas. conditions data into MVS
CAUSE
Erroneous manipulation of measuring conditions (test vision system / component; “Rucksack” file
from line computer faulty (part of GF file which can be manipulated)
REMEDY
Undo manipulation; delete “Rucksack” file in the line computer or assign new GF number
565 Error during loading of fiducials into MVS
CAUSE
Fiducial data from the line computer or station computer disk are erroneous; incorrect MVS
Eprom version
REMEDY
Delete fiducial data and teach them again; check MVS Eprom version
566 Error while loading fiducial centering param. into MVS
CAUSE
Fiducial data from the line computer or station computer disk are erroneous; incorrect MVS
Eprom version
REMEDY
Delete fiducial data and teach them again; check MVS Eprom version
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
63
567 Error while loading coplanarity data into module
CAUSE
Coplanarity has been selected for BGAs; erroneous GF description in the line computer
REMEDY
Deactivate coplanarity option; check GF description
568 Error while loading parameter pool into MVS
CAUSE
Erroneous data in the SST.ma file; incorrect MVS Eprom version
REMEDY
Check the SST.ma file; check the MVS Eprom version
569 Limited feeder position recognition
CAUSE
Feeder fiducials are outside the travel range of the main axes
REMEDY
Set feeder up for locations which lie within the travel range of the board camera
570 Nozzle not picked up from <magazine/garage>:
CAUSE
Garage indicated of the magazine in question is already empty; x, y or z positions are not correct
(real.ma)
REMEDY
Set magazine full; check the garage in question
571 Nozzle not returned to <magazine/garage>:
CAUSE
Garage indicated of the magazine in question is already occupied; x, y or z positions are not cor-
rect (real.ma)
REMEDY
Nozzle is discarded into rejects tray; check the garage in question
572 Nozzle type not available <type/for segment>:
CAUSE
Nozzle type displayed has not been set up or the corresponding magazine is empty
REMEDY
Fill magazine or insert by hand and confirm in the menu
573 Nozzle type not returnable <type/from segment>:
CAUSE
Magazine displayed has not been set up for this nozzle type or the magazine is full
REMEDY
Nozzle is discarded into the rejects tray