00191494-01 - 第65页
Short Reference SIPLACE 80 S-15/F3/G Error Messages 03/99 Issue Software Version SR.010.x x 63 567 Error while loading coplanarity da ta into module CAUSE ● Coplanarity has been selecte d for BGAs; erroneous GF d escript…
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
62
560 Error during execution of SP nozzle head check
CAUSE
● Error in program run
In the menu "General errors" the following applies to Info1:
Info1 = 1 Setting up not necessary
Info1 = 2 Magazine no. invalid
Info1 = 3 Segment no. invalid
Info1 = 4 Garage not found
REMEDY
● Notify Siemens Service.
561 Modify SP head nozzle-changer
CAUSE
● The corresponding nozzle type has not been set up in the nozzle-changer
REMEDY
● Modify nozzle-changer set-up in accordance with required specification and confirm in the menu
with the return key.
562 Error while loading GF geom. description data into MVS
CAUSE
● Camera records in real.ma are erroneous; old MVS Eprom version; GF description (line compu-
ter) erroneous; incorrect sensor system type input at line computer
REMEDY
● Check camera records (real.ma); check Eprom MVS version
563 Error while loading GF meas. conditions data into MVS
CAUSE
● Erroneous manipulation of measuring conditions (test vision system / component; “Rucksack” file
from line computer faulty (part of GF file which can be manipulated)
REMEDY
● Undo manipulation; delete “Rucksack” file in the line computer or assign new GF number
565 Error during loading of fiducials into MVS
CAUSE
● Fiducial data from the line computer or station computer disk are erroneous; incorrect MVS
Eprom version
REMEDY
● Delete fiducial data and teach them again; check MVS Eprom version
566 Error while loading fiducial centering param. into MVS
CAUSE
● Fiducial data from the line computer or station computer disk are erroneous; incorrect MVS
Eprom version
REMEDY
● Delete fiducial data and teach them again; check MVS Eprom version
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
63
567 Error while loading coplanarity data into module
CAUSE
● Coplanarity has been selected for BGAs; erroneous GF description in the line computer
REMEDY
● Deactivate coplanarity option; check GF description
568 Error while loading parameter pool into MVS
CAUSE
● Erroneous data in the SST.ma file; incorrect MVS Eprom version
REMEDY
● Check the SST.ma file; check the MVS Eprom version
569 Limited feeder position recognition
CAUSE
● Feeder fiducials are outside the travel range of the main axes
REMEDY
● Set feeder up for locations which lie within the travel range of the board camera
570 Nozzle not picked up from <magazine/garage>:
CAUSE
● Garage indicated of the magazine in question is already empty; x, y or z positions are not correct
(real.ma)
REMEDY
● Set magazine full; check the garage in question
571 Nozzle not returned to <magazine/garage>:
CAUSE
● Garage indicated of the magazine in question is already occupied; x, y or z positions are not cor-
rect (real.ma)
REMEDY
● Nozzle is discarded into rejects tray; check the garage in question
572 Nozzle type not available <type/for segment>:
CAUSE
● Nozzle type displayed has not been set up or the corresponding magazine is empty
REMEDY
● Fill magazine or insert by hand and confirm in the menu
573 Nozzle type not returnable <type/from segment>:
CAUSE
● Magazine displayed has not been set up for this nozzle type or the magazine is full
REMEDY
● Nozzle is discarded into the rejects tray
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
64
574 Feeder position recognition not possible
CAUSE
● Conveyor fiducials are outside the travel range of the main axes
REMEDY
● Set up the conveyor for locations which are within the travel range of the board camera
575 Incorrect centering device setting for component concerned
CAUSE
● Incorrect entry in the line computer GF editor.
REMEDY
● Change the processing data for the package form in the line computer GF editor.
576 Incorrect placement sequence in cluster data
CAUSE
● Inconsistency in the cluster data
TO RECTIFY
● Generate a new placement sequence on the line computer. Notify Siemens Service.
578 Nozzle not ejected into rejects box
CAUSE
● The component or the nozzle is jamming at the rejects box.
The rejects box is full.
REMEDY
● Use the SITEST program to record the x, y and z nozzle positions.
Remove the obstacle or empty the rejects box.
579 Coplan: Bad component, to be returned
CAUSE
● Lead height outside tolerance.
TO RECTIFY
● Discard the component.
580 Copl: Comp. cannot be measured (ex. offset)
CAUSE
● Coplanarity measurement not possible due to results of optical centering measurement.
TO RECTIFY
● Discard the component.