00191494-01 - 第70页

Error Messages Short Reference SIPLACE 80 S-15/F3/G 03/99 Issue Software Version SR.010.x x 68 715 BO: Error in pause (sts) CAUSE ● System error during syst em call P AUSE. REMEDY ● When the machine is a t a standstill, …

100%1 / 124
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
67
708 CRDL 2 configured without mechanical centering
CAUSE
Despite the CRDL tester, the mechanical centering station has not been configured (tester wit-
hout mechanical centering station is not possible)
REMEDY
Correct the configuration in the line computer for this station.
709 BO: Event flag ID unknown (flag id)
CAUSE
System error during system call SVC-Look for event flag group of the keyboard task
REMEDY
When the machine is at a standstill, reset the machine.
710 BO: Error in RIO. HSFS_XREAD (sts)
CAUSE
System error during keyboard input.
REMEDY
When the machine is at a standstill, reset the machine.
711 BO: 1st state byte HSFS_XREAD (status[0])
CAUSE
System error during keyboard input.
REMEDY
When the machine is at a standstill, reset the machine.
712 BO: Error in RIO POLL_XBUF (sts)
CAUSE
System error during keyboard input.
REMEDY
When the machine is at a standstill, reset the machine.
713 BO: 1st status byte POLL_XBUF (status[0])
CAUSE
System error during keyboard input.
REMEDY
When the machine is at a standstill, reset the machine.
714 NF: no memory available
CAUSE
System error
REMEDY
Reboot
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
68
715 BO: Error in pause (sts)
CAUSE
System error during system call PAUSE.
REMEDY
When the machine is at a standstill, reset the machine.
716 BO Barcode terminator not found
CAUSE
The terminator is missing after the barcode header, barcode at the barcode pen not recognized.
REMEDY
Reread the barcode. If this does not work, check the barcode header and terminator.
717 BO: 1st character of barcode terminator not found
CAUSE
The terminator is missing after the barcode header, barcode at the barcode pen not recognized.
REMEDY
Reread the barcode. If this does not work, check the barcode header and terminator.
718 VS: Unknown message code
CAUSE
Software error
REMEDY
Inform Siemens Service; possibly reboot.
719 VS: Error during system call look
CAUSE
Software error
REMEDY
Inform Siemens Service; possibly reboot.
720 VS: File could not be opened
CAUSE
File does not exist in the station computer
REMEDY
Reinstall software
721 VS: Error in fiducial data
CAUSE
Fiducial data erroneous; obsolete ICOS version
REMEDY
Reset ICOS, update eproms
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
69
722 VS: Error during memory request
CAUSE
Software error
REMEDY
Reboot; inform Siemens Service.
723 VS: File could not be opened
CAUSE
File does not exist in the station computer (TISCH.HEX)
REMEDY
Reinstall software (possibly only TISCH.HEX)
724 VS: Error during memory request
CAUSE
Not enough memory available in the station computer
REMEDY
Reset station computer
725 VS: Error during memory release in VS load
CAUSE
Software error
REMEDY
Inform Siemens Service.
726 VS: Error in message reception
CAUSE
Software error
REMEDY
Inform Siemens Service; possibly reboot.
727 VS: Error in send function in SC
CAUSE
Software error
REMEDY
Inform Siemens Service; possibly reboot.
728 VS: Unknown state
CAUSE
Software error
REMEDY
Inform Siemens Service; possibly reboot.