Short Reference SIPLACE 80 S-15/F3/G Error Messages 03/99 Issue Software Version SR.010.x x 69 722 VS: Error during memory request CAUSE ● Software error REMEDY ● Reboot; inform Siemens Servic e. 723 VS: File could not b…
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
68
715 BO: Error in pause (sts)
CAUSE
● System error during system call PAUSE.
REMEDY
● When the machine is at a standstill, reset the machine.
716 BO Barcode terminator not found
CAUSE
● The terminator is missing after the barcode header, barcode at the barcode pen not recognized.
REMEDY
● Reread the barcode. If this does not work, check the barcode header and terminator.
717 BO: 1st character of barcode terminator not found
CAUSE
● The terminator is missing after the barcode header, barcode at the barcode pen not recognized.
REMEDY
● Reread the barcode. If this does not work, check the barcode header and terminator.
718 VS: Unknown message code
CAUSE
● Software error
REMEDY
● Inform Siemens Service; possibly reboot.
719 VS: Error during system call look
CAUSE
● Software error
REMEDY
● Inform Siemens Service; possibly reboot.
720 VS: File could not be opened
CAUSE
● File does not exist in the station computer
REMEDY
● Reinstall software
721 VS: Error in fiducial data
CAUSE
● Fiducial data erroneous; obsolete ICOS version
REMEDY
● Reset ICOS, update eproms
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
69
722 VS: Error during memory request
CAUSE
● Software error
REMEDY
● Reboot; inform Siemens Service.
723 VS: File could not be opened
CAUSE
● File does not exist in the station computer (TISCH.HEX)
REMEDY
● Reinstall software (possibly only TISCH.HEX)
724 VS: Error during memory request
CAUSE
● Not enough memory available in the station computer
REMEDY
● Reset station computer
725 VS: Error during memory release in VS load
CAUSE
● Software error
REMEDY
● Inform Siemens Service.
726 VS: Error in message reception
CAUSE
● Software error
REMEDY
● Inform Siemens Service; possibly reboot.
727 VS: Error in send function in SC
CAUSE
● Software error
REMEDY
● Inform Siemens Service; possibly reboot.
728 VS: Unknown state
CAUSE
● Software error
REMEDY
● Inform Siemens Service; possibly reboot.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
70
729 VS: Upload data incorrect
CAUSE
● Obsolete MVS software, MVS error.
REMEDY
● Reboot; update eproms (MVS).
730 NF: software error
CAUSE
● Incorrect message at NF (Info1)
REMEDY
● If possible, ignore; possibly reboot.
731 NF: GLC NOK
CAUSE
● Internal transmission error
REMEDY
● Try again; if possible, ignore.
732 MA data: unknown spacer type
CAUSE
● In aktuell.ma or *.vkl there is a spacer type which cannot be found in real.ma.
REMEDY
● Establish consistency in the files aktuell.ma, *vkl and real.ma.
733 SF: unexpected input:
CAUSE
● Incorrect message to single function (Info1), operator error during transition to single function or
fatal error handling ( start button not pressed )
REMEDY
● If possible, ignore; possibly reboot.
734 SF: answer from wrong MC
CAUSE
● System error
REMEDY
● Reboot
735 SF: global communication not ok
CAUSE
● Communication between machine controller and station computer disturbed.
REMEDY
● Try communicating again.