Short Reference SIPLACE 80 S-15/F3/G Error Messages 03/99 Issue Software Version SR.010.x x 71 736 GK: Error in local machine data CAUSE ● There are no real or current m achine data on the hard d isk; the machine data ca…
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
70
729 VS: Upload data incorrect
CAUSE
● Obsolete MVS software, MVS error.
REMEDY
● Reboot; update eproms (MVS).
730 NF: software error
CAUSE
● Incorrect message at NF (Info1)
REMEDY
● If possible, ignore; possibly reboot.
731 NF: GLC NOK
CAUSE
● Internal transmission error
REMEDY
● Try again; if possible, ignore.
732 MA data: unknown spacer type
CAUSE
● In aktuell.ma or *.vkl there is a spacer type which cannot be found in real.ma.
REMEDY
● Establish consistency in the files aktuell.ma, *vkl and real.ma.
733 SF: unexpected input:
CAUSE
● Incorrect message to single function (Info1), operator error during transition to single function or
fatal error handling ( start button not pressed )
REMEDY
● If possible, ignore; possibly reboot.
734 SF: answer from wrong MC
CAUSE
● System error
REMEDY
● Reboot
735 SF: global communication not ok
CAUSE
● Communication between machine controller and station computer disturbed.
REMEDY
● Try communicating again.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
71
736 GK: Error in local machine data
CAUSE
● There are no real or current machine data on the hard disk; the machine data cannot be conver-
ted due to a structure error.
REMEDY
● Write the MA data onto the hard disk properly.
737 GK: Error in machine data
CAUSE
● The MA data (ideal) coming from the line computer cannot be converted.
REMEDY
● The correct data format must be sent.
738 GK: Error in set-up data
CAUSE
● The set-up data coming from the line computer cannot be converted.
REMEDY
● The correct data format must be sent.
739 GK: Error in cluster data
CAUSE
● The cluster data coming from the line computer cannot be converted.
REMEDY
● The correct data format must be sent.
740 GK: Error in fiducial data
CAUSE
● The fiducial data coming from the line computer cannot be converted.
REMEDY
● The correct data format must be sent.
741 GK: Error in package form data
CAUSE
● The package form data coming from the line computer cannot be converted.
REMEDY
● The correct data format must be sent.
742 LRS: Timeout during transmission to line computer
CAUSE
● Released through IEC bus
REMEDY
● Reboot
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
72
744 LRS: Command not in command list
CAUSE
● LR SEND incorrect command received
REMEDY
● If possible, ignore.
745 LRS: Conversion is not possible
CAUSE
● Could not convert data for line computer telegrams SABR/SBES.
REMEDY
● No
746 LRS: No communication with line computer
CAUSE
● IEC bus is "blocked"
REMEDY
● Reboot station and line computers.
747 DP: Data limits exceeded
CAUSE
● Incorrect date input
REMEDY
● Correct input date
748 DP: required equipment unknown
CAUSE
● Possibly the TASKS.CFG file has been changed, or there is a software fault
REMEDY
● Reboot with the supplied version of TASKS.CFG ; if necessary, notify Siemens Service.
749 No PCB barcode read
CAUSE
● Barcode reader has been activated but barcode was not recognized
REMEDY
● Make sure the barcode type is correct; make sure the mechanical distance is correct
750 Data preparation : internal error
CAUSE
● Not possible to write to station computer hard disk.
REMEDY
● Check disk; disk full?; files write-protected ? (check *.MA, *.GF, *.NU, *.RU)