00191494-01 - 第75页

Short Reference SIPLACE 80 S-15/F3/G Error Messages 03/99 Issue Software Version SR.010.x x 73 751 Data preparation : run error CAUSE ● If there was previously an erro r in the placement data (MK /GF/RU/NU files) all oth…

100%1 / 124
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
72
744 LRS: Command not in command list
CAUSE
LR SEND incorrect command received
REMEDY
If possible, ignore.
745 LRS: Conversion is not possible
CAUSE
Could not convert data for line computer telegrams SABR/SBES.
REMEDY
No
746 LRS: No communication with line computer
CAUSE
IEC bus is "blocked"
REMEDY
Reboot station and line computers.
747 DP: Data limits exceeded
CAUSE
Incorrect date input
REMEDY
Correct input date
748 DP: required equipment unknown
CAUSE
Possibly the TASKS.CFG file has been changed, or there is a software fault
REMEDY
Reboot with the supplied version of TASKS.CFG ; if necessary, notify Siemens Service.
749 No PCB barcode read
CAUSE
Barcode reader has been activated but barcode was not recognized
REMEDY
Make sure the barcode type is correct; make sure the mechanical distance is correct
750 Data preparation : internal error
CAUSE
Not possible to write to station computer hard disk.
REMEDY
Check disk; disk full?; files write-protected ? (check *.MA, *.GF, *.NU, *.RU)
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
73
751 Data preparation : run error
CAUSE
If there was previously an error in the placement data (MK/GF/RU/NU files) all other telegrams
coming from the line computer will be discarded and in each case a message generated.
REMEDY
Reboot station (a great deal of specialist knowledge is required for precise identification of this
fault).
752 Data preparation : error in machine data
CAUSE
It was not possible to convert the MA data (files AKTUELL.MA, REAL.MA, IDEAL.MA,
RASTER.P1, RASTER.P2).
REMEDY
Check the hard disk for bad clusters with the DOS program using the CHKDSK command; rein-
stall machine data (files) onto the hard disk.
753 Data preparation : error in cluster data
CAUSE
It was not possible to convert the NU data.
REMEDY
The line computer has generated a faulty cluster, check data in line computer.
754 Data preparation : error in set-up data
CAUSE
It was not possible to convert the RU data.
REMEDY
The line computer has generated a faulty set-up, check data in line computer.
755 Data preparation : error in package form data
CAUSE
GF could not be converted.
REMEDY
Check GF in the line computer.
756 Data preparation : error in fiducial data
CAUSE
MK could not be converted.
REMEDY
If this occurs only with a pure SIPLACE line (with MVS) it is best simply to reteach the MK.
758 LR: Error reading telegram
CAUSE
Separators or value fields in the line computer telegram are incorrect or overrun.
REMEDY
Check hard disk of the station (MS-DOS CHKDSK); reboot.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
74
761 LR: No memory, task stopped
CAUSE
Memory of the station is not fragmented.
REMEDY
Reboot station.
762 VS: Maximal gradient number of fiducial profile exceeded
CAUSE
Fiducial structure with poor contrast value as background; horizontal / vertical fiducial profile
which contains more than 100 gradients which reach 20% of maximum gradients.
REMEDY
Reduce template field, select another fiducial structure.
763 BO: Error dur. memory request f. text pool (no./length)
CAUSE
System error, not enough memory available.
REMEDY
Inform Siemens Service
764 BO: Cannot open text file
CAUSE
Text file not found.
REMEDY
The name of the text file is in the file C:\Texte\SITXT.CFG. If this file does not exist, the software
must be reinstalled.
765 BO: Text index too large (text index/max index)
CAUSE
A text in the text file is too large.
REMEDY
Ignore but inform Siemens Service.
766 BO: Text index defined twice (text index/i. )
CAUSE
On loading texts, double text indices were detected. Loading is repeated.
REMEDY
Ignore, but inform Siemens Service.
767 PCB barcode: incorrect format
CAUSE
The machine has not identified the board barcode received from the barcode reader.
REMEDY
Input manually via the keyboard or try again. Once placement of the current board is complete the
error menu will drop down.