00191494-01 - 第77页

Short Reference SIPLACE 80 S-15/F3/G Error Messages 03/99 Issue Software Version SR.010.x x 75 768 No data received from PCB barcod e reader CAUSE ● PCB barcode reader not resp onding. REMEDY ● Check PCB barcode reader. …

100%1 / 124
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
74
761 LR: No memory, task stopped
CAUSE
Memory of the station is not fragmented.
REMEDY
Reboot station.
762 VS: Maximal gradient number of fiducial profile exceeded
CAUSE
Fiducial structure with poor contrast value as background; horizontal / vertical fiducial profile
which contains more than 100 gradients which reach 20% of maximum gradients.
REMEDY
Reduce template field, select another fiducial structure.
763 BO: Error dur. memory request f. text pool (no./length)
CAUSE
System error, not enough memory available.
REMEDY
Inform Siemens Service
764 BO: Cannot open text file
CAUSE
Text file not found.
REMEDY
The name of the text file is in the file C:\Texte\SITXT.CFG. If this file does not exist, the software
must be reinstalled.
765 BO: Text index too large (text index/max index)
CAUSE
A text in the text file is too large.
REMEDY
Ignore but inform Siemens Service.
766 BO: Text index defined twice (text index/i. )
CAUSE
On loading texts, double text indices were detected. Loading is repeated.
REMEDY
Ignore, but inform Siemens Service.
767 PCB barcode: incorrect format
CAUSE
The machine has not identified the board barcode received from the barcode reader.
REMEDY
Input manually via the keyboard or try again. Once placement of the current board is complete the
error menu will drop down.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
75
768 No data received from PCB barcode reader
CAUSE
PCB barcode reader not responding.
REMEDY
Check PCB barcode reader.
769 Barcode too long, cut off!
CAUSE
The maximum permissible length of the board barcode is 25 characters, of the component 20
characters; a longer barcode was received, but was cut short.
REMEDY
The machine carries on working with the shortened barcode.
770 BL: unexpected input
CAUSE
System error
REMEDY
If possible, ignore.
771 VS: Communication between SR and MC defective
CAUSE
Software error
REMEDY
Reboot, if occurs repeatedly inform Siemens Service.
772 EH: received CODE unknown
CAUSE
Incorrect message to task EH.
REMEDY
If possible, ignore.
773 EH: received IDENT unknown
CAUSE
Incorrect message to task EH.
REMEDY
If possible, ignore.
774 EH: MC sending too many error messages (> F_FM_MAX)
CAUSE
Error handling can receive a maximum of 200 error messages at the same time from the machine
controller.
REMEDY
The error messages > 200 are discarded.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
76
776 AKT: Error during system call ALOC
CAUSE
No memory allocated to Task T_AKT.
REMEDY
Reboot.
777 AKT: Incorrect input
CAUSE
Task AKT has received unknown message.
REMEDY
If possible, ignore, otherwise reboot.
778 AKT: Wrong data from data preparation
CAUSE
Data preparation sending incorrect "AKTUELL.MA" format to task T_AKT.
REMEDY
System error, reboot.
779 LRR: Undefined operation with and without LC
CAUSE
The station computer receives a message from the line computer, but it was input at station com-
puter as "without LC".
REMEDY
Input mode "with LC" at the station computer.
780 LRR: Undefined error in LC reception
CAUSE
Error when receiving via IEC bus.
REMEDY
Reboot.
781 LRR: No memory available
CAUSE
Memory in station computer is fragmented.
REMEDY
Reboot.
782 LRR: Defective or incomplete telegram from LC
CAUSE
Unknown telegram from the line computer (may be incomplete)
REMEDY
Respecify placement program in the line computer.