00191494-01 - 第82页

Error Messages Short Reference SIPLACE 80 S-15/F3/G 03/99 Issue Software Version SR.010.x x 80 804 BO: POOL cannot be given b ack (length); CAUSE ● A requested memory ar ea can no longer be return ed, system error . REME…

100%1 / 124
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
79
797 BO: Text line interrupted at type (character/i)
CAUSE
Contents of the text file are faulty.
REMEDY
If the error occurs again after error message 704, reset station.
798 BO: Text line interrupted at name (character/i)
CAUSE
Contents of the text file are faulty.
REMEDY
If the error occurs again after error message 704, reset station.
799 BO: Unknown state while loading texts (state)
CAUSE
System error while loading the texts.
REMEDY
Reset station.
800 BO: Text too long (text index/actual length)
CAUSE
A text is longer than permitted.
REMEDY
If the error occurs again after error message 704, inform Siemens Service.
801 BO: Invalid length information (text index/ith char)
CAUSE
Contents of the text file are faulty.
REMEDY
If the error occurs again after error message 704, reset station.
802 BO: Postponement line full (ident/code)
CAUSE
The operator interface is receiving too many jobs and cannot process these.
REMEDY
Reset station.
803 BO: Insufficient memory for postponement (length)
CAUSE
No memory available.
REMEDY
Reset station.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
80
804 BO: POOL cannot be given back (length);
CAUSE
A requested memory area can no longer be returned, system error.
REMEDY
Reset station.
805 BO: Message cannot be sent (state/code)
CAUSE
Error during system call "send" or not enough memory available.
REMEDY
Reset station.
806 NF: unexpected input
CAUSE
System error
REMEDY
If possible, ignore
807 KLKONF: System error during initialization
CAUSE
Software error in glueing configuration task
REMEDY
Reboot
808 KLKONF: System error during memory request
CAUSE
Software error in glueing configuration task during memory request
REMEDY
Reboot
809 KLKONF: System error during give back memory
CAUSE
Software error in glueing configuration task during give back of memory
REMEDY
Reboot
810 KLKONF: System error during send message
CAUSE
Software error in glueing configuration task during send message
REMEDY
Reboot
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
81
811 KLKONF: Incorrect input
CAUSE
Software error in glueing configuration task; Incorrect message received
REMEDY
Reboot
812 KLKONF: Invalid input data
CAUSE
Software error in glueing configuration task; Incorrect data received from data preparation
REMEDY
Reboot; get the data organized
813 WARNING: Glue data from file ".ZKL" invalid
CAUSE
1. No *.ZKL can be found (with glueing parameters which have not yet been manipulated).
2. Data from "ZKL" incorrect.
REMEDY
To 1. Not an error
To 2. Delete *.ZKL, manipulate, then a new *.ZKL will be created.
814 Glueing data cannot be modified
CAUSE
Software error
REMEDY
Reboot
815 DP: Incorrect operating system call
CAUSE
Software error
REMEDY
Siemens Service should be notified.
816 DP: No LC command in service without LC
CAUSE
Machine in "service without line computer" but all the same command received via IEC bus.
REMEDY
Machines and line configuration should be checked.
817 DP: Set-up without valid machine data
CAUSE
Incorrect data supply from the line computer.
REMEDY
Data supply from the line computer should be checked.