00191494-01 - 第84页

Error Messages Short Reference SIPLACE 80 S-15/F3/G 03/99 Issue Software Version SR.010.x x 82 818 DP: Cluster without valid set-u p data CAUSE ● Incorrect data supply fr om the line computer. REMEDY ● Data supply from t…

100%1 / 124
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
81
811 KLKONF: Incorrect input
CAUSE
Software error in glueing configuration task; Incorrect message received
REMEDY
Reboot
812 KLKONF: Invalid input data
CAUSE
Software error in glueing configuration task; Incorrect data received from data preparation
REMEDY
Reboot; get the data organized
813 WARNING: Glue data from file ".ZKL" invalid
CAUSE
1. No *.ZKL can be found (with glueing parameters which have not yet been manipulated).
2. Data from "ZKL" incorrect.
REMEDY
To 1. Not an error
To 2. Delete *.ZKL, manipulate, then a new *.ZKL will be created.
814 Glueing data cannot be modified
CAUSE
Software error
REMEDY
Reboot
815 DP: Incorrect operating system call
CAUSE
Software error
REMEDY
Siemens Service should be notified.
816 DP: No LC command in service without LC
CAUSE
Machine in "service without line computer" but all the same command received via IEC bus.
REMEDY
Machines and line configuration should be checked.
817 DP: Set-up without valid machine data
CAUSE
Incorrect data supply from the line computer.
REMEDY
Data supply from the line computer should be checked.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
82
818 DP: Cluster without valid set-up data
CAUSE
Incorrect data supply from the line computer.
REMEDY
Data supply from the line computer should be checked.
819 DP: Package form without valid set-up data
CAUSE
Incorrect data supply from the line computer.
REMEDY
Data supply from the line computer should be checked.
820 DP: Delete package form without valid set-up data
CAUSE
Incorrect data supply from the line computer.
REMEDY
Data supply from the line computer should be checked.
821 DP: Set-up and cluster without valid machine data
CAUSE
Incorrect data supply from the line computer.
REMEDY
Data supply from the line computer should be checked.
822 DP: Error in the data supply from LC
CAUSE
Incorrect data supply from the line computer.
REMEDY
Data supply from the line computer should be checked.
823 DP: Invalid request from vision task
CAUSE
Software error in operation DP with vision system
REMEDY
Reboot
824 DP: Fiducial telegram in mixed line not allowed
CAUSE
Fiducial telegram sent to SIPLACE from line computer in mixed line.
REMEDY
Check configuration.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
83
825 DP: Unknown message received
CAUSE
Software error
REMEDY
Reboot
826 DP: Error while updating the int. global data
CAUSE
Software error
REMEDY
Reboot
827 DP: Error while creating int. list for pack. form data
CAUSE
Software error
REMEDY
Reboot
828 DP: No more storing capacity available
CAUSE
Station computer has no more memory capacity left
REMEDY
Data too large (set-up, cluster, ....); reboot
829 DP: Error in local communication
CAUSE
Software error
REMEDY
Reboot
830 DP: Error during equipment cataloging
CAUSE
Software error
REMEDY
Reboot
831 DP: Dynam. equipment cannot be generated
CAUSE
Software error
REMEDY
Reboot