00191494-01 - 第85页

Short Reference SIPLACE 80 S-15/F3/G Error Messages 03/99 Issue Software Version SR.010.x x 83 825 DP: Unknown message received CAUSE ● Software error REMEDY ● Reboot 826 DP: Error while updating the int. glo bal data CA…

100%1 / 124
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
82
818 DP: Cluster without valid set-up data
CAUSE
Incorrect data supply from the line computer.
REMEDY
Data supply from the line computer should be checked.
819 DP: Package form without valid set-up data
CAUSE
Incorrect data supply from the line computer.
REMEDY
Data supply from the line computer should be checked.
820 DP: Delete package form without valid set-up data
CAUSE
Incorrect data supply from the line computer.
REMEDY
Data supply from the line computer should be checked.
821 DP: Set-up and cluster without valid machine data
CAUSE
Incorrect data supply from the line computer.
REMEDY
Data supply from the line computer should be checked.
822 DP: Error in the data supply from LC
CAUSE
Incorrect data supply from the line computer.
REMEDY
Data supply from the line computer should be checked.
823 DP: Invalid request from vision task
CAUSE
Software error in operation DP with vision system
REMEDY
Reboot
824 DP: Fiducial telegram in mixed line not allowed
CAUSE
Fiducial telegram sent to SIPLACE from line computer in mixed line.
REMEDY
Check configuration.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
83
825 DP: Unknown message received
CAUSE
Software error
REMEDY
Reboot
826 DP: Error while updating the int. global data
CAUSE
Software error
REMEDY
Reboot
827 DP: Error while creating int. list for pack. form data
CAUSE
Software error
REMEDY
Reboot
828 DP: No more storing capacity available
CAUSE
Station computer has no more memory capacity left
REMEDY
Data too large (set-up, cluster, ....); reboot
829 DP: Error in local communication
CAUSE
Software error
REMEDY
Reboot
830 DP: Error during equipment cataloging
CAUSE
Software error
REMEDY
Reboot
831 DP: Dynam. equipment cannot be generated
CAUSE
Software error
REMEDY
Reboot
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
84
832 DP: Conversion job without input data
CAUSE
Software error
REMEDY
Reboot
833 DP: Error during conversion of MC structures
CAUSE
Software error
REMEDY
Reboot
834 DP: Error while writing MC structures on HD
CAUSE
Data could not be written to hard disk.
REMEDY
Hard disk and hardware should be checked.
835 DP: Transfer to MC not possible
CAUSE
Software error
REMEDY
Reboot
836 DP: Missing file name for PF
CAUSE
PF could not be found
REMEDY
Check data
837 DP: Cannot open package form file
CAUSE
An error occurred while the file was being read
REMEDY
Hard disk and file should be checked
838 DP: Missing file name
CAUSE
File could not be found
REMEDY
Check data