00191494-01 - 第88页
Error Messages Short Reference SIPLACE 80 S-15/F3/G 03/99 Issue Software Version SR.010.x x 86 846 DP: Loading of pack. form or fid. data not successful CAUSE ● Error while reading and loading the package form o r fiduci…
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
85
839 DP: Cannot open file
CAUSE
● An error occurred while the file was being read
REMEDY
● Hard disk and file should be checked
840 DP: Cannot write file
CAUSE
● While the file was being written an error occurred
REMEDY
● Hard disk, file and file attribute (Read/Write) should be checked
841 DP: Cannot log on drive
CAUSE
● Hardware error
REMEDY
● Hardware and hard disk should be checked
842 DP: Cannot log off drive
CAUSE
● Hardware error
REMEDY
● Hardware and hard disk should be checked
843 DP: Cannot open fiducial file
CAUSE
● Error while reading the fiducial file
REMEDY
● Hard disk and file should be checked
844 DP: Cannot open fiducial list file
CAUSE
● Error while reading the fiducial list file
REMEDY
● Hard disk and file should be checked
845 DP: Head in local files wrong or incomplete
CAUSE
● Incorrect head entered in machine data
REMEDY
● Check machine data
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
86
846 DP: Loading of pack. form or fid. data not successful
CAUSE
● Error while reading and loading the package form or fiducial data.
REMEDY
● Data of package form and fiducial file should be checked
847 DP: Error in list for passpoint sets and fiducials
CAUSE
● Error in real.ma and fiducial file
REMEDY
● Data in real and fiducial files should be checked
848 File AKTUELL.MA cannot be stored
CAUSE
● Changing and rewriting aktuell.ma is not possible
REMEDY
● Hard disk should be checked
849 VKL file cannot be stored
CAUSE
● Not possible to rewrite the *.VKL file
REMEDY
● Hard disk should be checked
850 Process data cannot be stored
CAUSE
● Not possible to rewrite the glueing head process switches (C:\TMP\VL_PDAT.K1/2/3)
REMEDY
● Hard disk should be checked
851 Process data cannot be read
CAUSE
● 1. At first time still no process data found
2. Error occurred during read
REMEDY
● To 1. Not an error
To 2. File and hard disk should be checked
852 Data preparation: Cannot save current MA data
CAUSE
● Not possible to change or rewrite the aktuell.ma file
REMEDY
● Hard disk should be checked
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
87
853 MA data: Invalid fiducial number for system fiducial
CAUSE
● System fiducials must lie within the range 250 to 255
REMEDY
● Correct the fiducial data in the MA data or set-up.
854 MA data: Error in sensor system types
CAUSE
● Different sensor system types, or invalid for machine, in real.ma and ideal.ma
quoted (line computer telegram).
REMEDY
● Make data consistent.
855 MA data: Missing height offset
CAUSE
● Height offset not entered in real.ma.
REMEDY
● Measure height offset and enter in real.ma.
856 MA data: Too many zero point fiducials
CAUSE
● More than one zero point fiducial has been entered in ideal.ma.
REMEDY
● Enter one fiducial only.
857 MA data: Mapping plate irregular
CAUSE
● Irregular mapping plate is not supported.
REMEDY
● Raster.px file should be checked; if necessary, remeasure
858 MA data: Error in nozzle type/vacuum correction values
CAUSE
● For nozzle type in aktuell.ma no vacuum correction values can be found.
REMEDY
● Enter valid nozzle type in aktuell.ma.
859 MA data: Invalid compartment at nozzle changer
CAUSE
● An invalid compartment number has been entered in aktuell.ma or real.ma
REMEDY