00191494-01 - 第89页

Short Reference SIPLACE 80 S-15/F3/G Error Messages 03/99 Issue Software Version SR.010.x x 87 853 MA data: Invalid fiducial number for system fiducial CAUSE ● System fiducials must lie within the range 250 to 255 REMEDY…

100%1 / 124
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
86
846 DP: Loading of pack. form or fid. data not successful
CAUSE
Error while reading and loading the package form or fiducial data.
REMEDY
Data of package form and fiducial file should be checked
847 DP: Error in list for passpoint sets and fiducials
CAUSE
Error in real.ma and fiducial file
REMEDY
Data in real and fiducial files should be checked
848 File AKTUELL.MA cannot be stored
CAUSE
Changing and rewriting aktuell.ma is not possible
REMEDY
Hard disk should be checked
849 VKL file cannot be stored
CAUSE
Not possible to rewrite the *.VKL file
REMEDY
Hard disk should be checked
850 Process data cannot be stored
CAUSE
Not possible to rewrite the glueing head process switches (C:\TMP\VL_PDAT.K1/2/3)
REMEDY
Hard disk should be checked
851 Process data cannot be read
CAUSE
1. At first time still no process data found
2. Error occurred during read
REMEDY
To 1. Not an error
To 2. File and hard disk should be checked
852 Data preparation: Cannot save current MA data
CAUSE
Not possible to change or rewrite the aktuell.ma file
REMEDY
Hard disk should be checked
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
87
853 MA data: Invalid fiducial number for system fiducial
CAUSE
System fiducials must lie within the range 250 to 255
REMEDY
Correct the fiducial data in the MA data or set-up.
854 MA data: Error in sensor system types
CAUSE
Different sensor system types, or invalid for machine, in real.ma and ideal.ma
quoted (line computer telegram).
REMEDY
Make data consistent.
855 MA data: Missing height offset
CAUSE
Height offset not entered in real.ma.
REMEDY
Measure height offset and enter in real.ma.
856 MA data: Too many zero point fiducials
CAUSE
More than one zero point fiducial has been entered in ideal.ma.
REMEDY
Enter one fiducial only.
857 MA data: Mapping plate irregular
CAUSE
Irregular mapping plate is not supported.
REMEDY
Raster.px file should be checked; if necessary, remeasure
858 MA data: Error in nozzle type/vacuum correction values
CAUSE
For nozzle type in aktuell.ma no vacuum correction values can be found.
REMEDY
Enter valid nozzle type in aktuell.ma.
859 MA data: Invalid compartment at nozzle changer
CAUSE
An invalid compartment number has been entered in aktuell.ma or real.ma
REMEDY
Make the data consistent again.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
88
860 MA data: Unknown nozzle changer
CAUSE
An invalid nozzle changer type has been specified in aktuell.ma or real.ma.
REMEDY
Make the data consistent again.
861 Clust. data: Error in nozzle type/vac. correct. values
CAUSE
Error must not occur; for the nozzle type specified in the cluster nozzle type there are no vacuum
correction values in ideal.ma.
REMEDY
Check consistency in the line computer.
862 Clust. data: Error in chain of placement positions
CAUSE
Error in the line computer telegram for cluster
REMEDY
Cluster should be checked in the line computer ; if necessary, compile again (feasibility)
863 Clust. data: Error in passpoint sets
CAUSE
Error in the line computer telegram for cluster.
REMEDY
Cluster should be checked in the line computer; if necessary, compile again (feasibility).
864 Clust. data: incorrect track number
CAUSE
Incorrect track number in cluster or set-up.
REMEDY
Cluster and set-up should be checked in the line computer; feasibility.
865 Clust. data: Error during creation of fiducial list
CAUSE
Software error
REMEDY
Siemens Service should be notified.
866 Clust. data: Number fiducials or passpoint to large
CAUSE
Cluster in the line computer contains too many fiducials or passpoints.
REMEDY
Cluster should be checked in the line computer; feasibility.