Error Messages Short Reference SIPLACE 80 S-15/F3/G 03/99 Issue Software Version SR.010.x x 88 860 MA data: Unknown nozzle cha nger CAUSE ● An invalid nozzle chang er type has been specified in aktuell.ma or real.ma. REM…
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
87
853 MA data: Invalid fiducial number for system fiducial
CAUSE
● System fiducials must lie within the range 250 to 255
REMEDY
● Correct the fiducial data in the MA data or set-up.
854 MA data: Error in sensor system types
CAUSE
● Different sensor system types, or invalid for machine, in real.ma and ideal.ma
quoted (line computer telegram).
REMEDY
● Make data consistent.
855 MA data: Missing height offset
CAUSE
● Height offset not entered in real.ma.
REMEDY
● Measure height offset and enter in real.ma.
856 MA data: Too many zero point fiducials
CAUSE
● More than one zero point fiducial has been entered in ideal.ma.
REMEDY
● Enter one fiducial only.
857 MA data: Mapping plate irregular
CAUSE
● Irregular mapping plate is not supported.
REMEDY
● Raster.px file should be checked; if necessary, remeasure
858 MA data: Error in nozzle type/vacuum correction values
CAUSE
● For nozzle type in aktuell.ma no vacuum correction values can be found.
REMEDY
● Enter valid nozzle type in aktuell.ma.
859 MA data: Invalid compartment at nozzle changer
CAUSE
● An invalid compartment number has been entered in aktuell.ma or real.ma
REMEDY
● Make the data consistent again.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
88
860 MA data: Unknown nozzle changer
CAUSE
● An invalid nozzle changer type has been specified in aktuell.ma or real.ma.
REMEDY
● Make the data consistent again.
861 Clust. data: Error in nozzle type/vac. correct. values
CAUSE
● Error must not occur; for the nozzle type specified in the cluster nozzle type there are no vacuum
correction values in ideal.ma.
REMEDY
● Check consistency in the line computer.
862 Clust. data: Error in chain of placement positions
CAUSE
● Error in the line computer telegram for cluster
REMEDY
● Cluster should be checked in the line computer ; if necessary, compile again (feasibility)
863 Clust. data: Error in passpoint sets
CAUSE
● Error in the line computer telegram for cluster.
REMEDY
● Cluster should be checked in the line computer; if necessary, compile again (feasibility).
864 Clust. data: incorrect track number
CAUSE
● Incorrect track number in cluster or set-up.
REMEDY
● Cluster and set-up should be checked in the line computer; feasibility.
865 Clust. data: Error during creation of fiducial list
CAUSE
● Software error
REMEDY
● Siemens Service should be notified.
866 Clust. data: Number fiducials or passpoint to large
CAUSE
● Cluster in the line computer contains too many fiducials or passpoints.
REMEDY
● Cluster should be checked in the line computer; feasibility.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
89
867 Clust. data: Invalid X/Y offset 0 in individual circuit
CAUSE
● Error in the line computer telegram; offset must not be 0.
REMEDY
● Cluster should be checked in the line computer; feasibility.
868 Clust. data: Invalid location for machine type
CAUSE
● Error in the cluster telegram
REMEDY
● Cluster and set-up should be checked in the line computer; feasibility
869 Clust. data: Incorrect reference in placement options
CAUSE
● Incorrect reference in the placement positions.
REMEDY
● Check line computer data.
870 Set-up data: Error during conversion of tracks
CAUSE
● Error during conversion of tracks.
REMEDY
● Check line computer data.
871 Set-up data: Missing track chain
CAUSE
● Software error
REMEDY
● Siemens Service should be notified.
872 Set-up data: Invalid location for machine type
CAUSE
● Faulty set-up telegram from the line computer
REMEDY
● Set-up should be checked; feasibility.
873 Set-up data: Unknown sensor system type
CAUSE
● Software error
REMEDY
● Siemens Service should be notified.