00191494-01 - 第91页

Short Reference SIPLACE 80 S-15/F3/G Error Messages 03/99 Issue Software Version SR.010.x x 89 867 Clust. data: Invalid X/Y offset 0 in i ndividual circuit CAUSE ● Error in the line computer tele gram; offset must not be…

100%1 / 124
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
88
860 MA data: Unknown nozzle changer
CAUSE
An invalid nozzle changer type has been specified in aktuell.ma or real.ma.
REMEDY
Make the data consistent again.
861 Clust. data: Error in nozzle type/vac. correct. values
CAUSE
Error must not occur; for the nozzle type specified in the cluster nozzle type there are no vacuum
correction values in ideal.ma.
REMEDY
Check consistency in the line computer.
862 Clust. data: Error in chain of placement positions
CAUSE
Error in the line computer telegram for cluster
REMEDY
Cluster should be checked in the line computer ; if necessary, compile again (feasibility)
863 Clust. data: Error in passpoint sets
CAUSE
Error in the line computer telegram for cluster.
REMEDY
Cluster should be checked in the line computer; if necessary, compile again (feasibility).
864 Clust. data: incorrect track number
CAUSE
Incorrect track number in cluster or set-up.
REMEDY
Cluster and set-up should be checked in the line computer; feasibility.
865 Clust. data: Error during creation of fiducial list
CAUSE
Software error
REMEDY
Siemens Service should be notified.
866 Clust. data: Number fiducials or passpoint to large
CAUSE
Cluster in the line computer contains too many fiducials or passpoints.
REMEDY
Cluster should be checked in the line computer; feasibility.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
89
867 Clust. data: Invalid X/Y offset 0 in individual circuit
CAUSE
Error in the line computer telegram; offset must not be 0.
REMEDY
Cluster should be checked in the line computer; feasibility.
868 Clust. data: Invalid location for machine type
CAUSE
Error in the cluster telegram
REMEDY
Cluster and set-up should be checked in the line computer; feasibility
869 Clust. data: Incorrect reference in placement options
CAUSE
Incorrect reference in the placement positions.
REMEDY
Check line computer data.
870 Set-up data: Error during conversion of tracks
CAUSE
Error during conversion of tracks.
REMEDY
Check line computer data.
871 Set-up data: Missing track chain
CAUSE
Software error
REMEDY
Siemens Service should be notified.
872 Set-up data: Invalid location for machine type
CAUSE
Faulty set-up telegram from the line computer
REMEDY
Set-up should be checked; feasibility.
873 Set-up data: Unknown sensor system type
CAUSE
Software error
REMEDY
Siemens Service should be notified.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
90
874 Set-up data: Invalid reference in set-up telegram
CAUSE
Faulty set-up telegram from the line computer.
REMEDY
Check line computer data.
875 Set-up data: Unknown nozzle changer type
CAUSE
Error in set-up telegram from line computer.
REMEDY
Check nozzle changer type in the line computer.
876 Set-up data: Unknown track type in set-up telegram
CAUSE
Faulty set-up telegram from the line computer.
REMEDY
Check line computer data.
877 Set-up data: Error while writing WPC set-up
CAUSE
It was not possible to access the hard disk.
REMEDY
Check hard disk (consistency, storage capacity)
878 PF data: first PF number = 0; PF telegram faulty
CAUSE
Transfer a zero into the PF telegram as PF number.
REMEDY
Check line computer data.
879 PF data: Unknown sensor system type
CAUSE
This type of sensor system does not exist for this machine type
REMEDY
Check line computer data.
880 PF data: Error in internal PF list
CAUSE
Software error
REMEDY
Siemens Service should be notified.