Short Reference SIPLACE 80 S-15/F3/G Error Messages 03/99 Issue Software Version SR.010.x x 93 895 DP: Range limits in telegram exce eded CAUSE ● T e legram from the line computer mutilated (I EC communication); local fi…

100%1 / 124
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
92
889 DP: Last part of telegram missing
CAUSE
Telegram from the line computer mutilated (IEC communication); local file mutilated by incorrect
editing; hard disk defective; interface versions line computer and station computer incompatible.
REMEDY
Check station computer / line computer software versions.
IEC - Check cables. Check file.
890 DP: Telegram incomplete
CAUSE
Telegram from the line computer mutilated (IEC communication); local file mutilated by incorrect
editing; hard disk defective; interface versions line computer and station computer incompatible.
REMEDY
Check station computer / line computer software versions.
IEC - Check cables. Check file.
891 DP: Invalid character in telegram
CAUSE
Telegram from the line computer mutilated (IEC communication); local file mutilated by incorrect
editing; hard disk defective; interface versions line computer and station computer incompatible.
REMEDY
Check station computer / line computer software versions.
IEC - Check cables. Check file.
892 DP: Invalid telegram or file structure
CAUSE
Telegram from the line computer mutilated (IEC communication); local file mutilated by incorrect
editing; hard disk defective; interface versions line computer and station computer incompatible.
REMEDY
Check station computer / line computer software versions.
IEC - Check cables. Check file.
893 DP: Invalid number format in telegram
CAUSE
Telegram from the line computer mutilated (IEC communication); local file mutilated by incorrect
editing; hard disk defective; interface versions line computer and station computer incompatible.
REMEDY
Check station computer / line computer software versions.
IEC - Check cables. Check file.
894 DP: Error in telegram description
CAUSE
Telegram from the line computer mutilated (IEC communication); local file mutilated by incorrect
editing; hard disk defective; interface versions line computer and station computer incompatible.
REMEDY
Check station computer / line computer software versions.
IEC - Check cables. Check file.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
93
895 DP: Range limits in telegram exceeded
CAUSE
Telegram from the line computer mutilated (IEC communication); local file mutilated by incorrect
editing; hard disk defective; interface versions line computer and station computer incompatible.
REMEDY
Check station computer / line computer software versions.
IEC - Check cables. Check file.
896 DP: String too long
CAUSE
Telegram from the line computer mutilated (IEC communication); local file mutilated by incorrect
editing; hard disk defective; interface versions line computer and station computer incompatible.
REMEDY
Check station computer / line computer software versions.
IEC - Check cables. Check file.
897 DP: Glue identification lines not available
CAUSE
In aktuell.ma the incorrect glue name was specified
REMEDY
Correct the data in aktuell.ma
898 DP: VKL data not available
CAUSE
A glue name specified in aktuell.ma is not available *.VKL file
REMEDY
Correct aktuell.ma and *.VKL file
899 DP: INI data not available
CAUSE
A glue name specified in aktuell.ma is not available as *.INI file
REMEDY
Correct aktuell.ma and *.INI file
900 OPT: Error during data reception
CAUSE
Software error between data preparation and glue optimization
REMEDY
Cluster data should be corrected; reboot
901 OPT: Error during memory request
CAUSE
Software error in glue optimization: no more memory available
REMEDY
Files may be too large; reboot
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
94
902 OPT: No memory received
CAUSE
Software error in glue optimization: no more memory available
REMEDY
Files may be too large; reboot
903 OPT: Error during look
CAUSE
Software error in glue optimization
REMEDY
Reboot
904 OPT: No glueing position received
CAUSE
Glue optimization received the glueing number "zero"
REMEDY
Check data
905 Glueing size not possible with glue available
CAUSE
Glueing size specified by the line computer in this cluster is not possible with the glue set up
REMEDY
Set up glue again
906 OPT: Glueing size received is invalid
CAUSE
Glueing size is larger than 20
REMEDY
Check data
907 OPT: Glueing position outside of travel range
CAUSE
Optimization received a position outside the travel range
REMEDY
Travel range and cluster should be checked
908 Caution: PCB transported through by line computer
CAUSE
Board barcode has been sent to line computer; the line computer does not have this barcode in
its list
REMEDY
Wrong board fed in; something wrong with the list in the line computer.