Short Reference SIPLACE 80 S-15/F3/G Error Messages 03/99 Issue Software Version SR.010.x x 95 909 DP: Glue type list KLL incorrectly l oaded CAUSE ● Faulty data (*.vkl, SIPLACE.K LL) on the hard disk REMEDY ● Check all …
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
94
902 OPT: No memory received
CAUSE
● Software error in glue optimization: no more memory available
REMEDY
● Files may be too large; reboot
903 OPT: Error during look
CAUSE
● Software error in glue optimization
REMEDY
● Reboot
904 OPT: No glueing position received
CAUSE
● Glue optimization received the glueing number "zero"
REMEDY
● Check data
905 Glueing size not possible with glue available
CAUSE
● Glueing size specified by the line computer in this cluster is not possible with the glue set up
REMEDY
● Set up glue again
906 OPT: Glueing size received is invalid
CAUSE
● Glueing size is larger than 20
REMEDY
● Check data
907 OPT: Glueing position outside of travel range
CAUSE
● Optimization received a position outside the travel range
REMEDY
● Travel range and cluster should be checked
908 Caution: PCB transported through by line computer
CAUSE
● Board barcode has been sent to line computer; the line computer does not have this barcode in
its list
REMEDY
● Wrong board fed in; something wrong with the list in the line computer.

Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
95
909 DP: Glue type list KLL incorrectly loaded
CAUSE
● Faulty data (*.vkl, SIPLACE.KLL) on the hard disk
REMEDY
● Check all *.vkl files (including file name in the file)
910 VS: Search for array index not successful
CAUSE
● The job file is not consistent
REMEDY
● Check the camera records in REAL.MA; check the job data (GF data) in the line computer.
911 OPT: Spacer in contact with glueing point
CAUSE
● Glueing points are too close together or their position relative to the spacer is not good.
REMEDY
● Reposition the spacer and reoptimize the cluster.
NOTE
The spacer angle must be input in the "Modify system data" menu.
912 DP: axis type incorrect in small gantry mapping data
CAUSE
● Incorrect axis type in the RASTER.K1 file (mapping data for glueing station for small gantries)
REMEDY
● Make the necessary correction in the machine file RASTER.K1 (axis type).
913 DP: Gantry ID error in small gantry mapping data
CAUSE
● Incorrect gantry identification in RASTER.K1 file (mapping data for glueing station for small gan-
tries)
REMEDY
● Make the necessary correction in the machine file RASTER.K1 (axis type).
1005 Z-axis; GU1: Bero at top does not react
CAUSE
● Z1-axis is not positioned high enough; Bero defective; Z1-axis is jamming
motor, controller, servo-amplifier defective.
REMEDY
● Check the components just mentioned.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
96
1006 Z-axis; GU2: Bero at top does not react
CAUSE
● Z2-axis is not positioned high enough; Bero defective; Z2-axis is jamming
motor, controller, servo-amplifier defective.
REMEDY
● Check the components just mentioned.
1007 Z-axis; GU3: Bero at top does not react
CAUSE
● Z3-axis is not positioned high enough; Bero defective; Z3-axis is jamming
motor, controller, servo-amplifier defective.
REMEDY
● Check the components just mentioned.
1010 Z-axis; GU1: cannot be moved any further upwards
CAUSE
● When the start button is pressed the Z1-axis is below the minimum position
REMEDY
● The servo-amplifier should be checked; slide the Z1-axis upwards by hand
1011 Z-axis; GU2: cannot be moved any further upwards
CAUSE
● When the start button is pressed the Z2-axis is below the minimum position
REMEDY
● The servo-amplifier should be checked; slide the Z2-axis upwards by hand
1012 Z-axis; GU3: cannot be moved any further upwards
CAUSE
● When the start button is pressed the Z3-axis is below the minimum position
REMEDY
● The servo-amplifier should be checked; slide the Z3-axis upwards by hand
1018 xk-axis: Target position not reached
CAUSE
● Machine data not correct; mechanism is jamming;
drive motor, tachometer, incremental encoder, servo-amplifier defective; calibration of the axis
incorrect.
REMEDY
● Check machine data; check the mechanism; check the axis calibration
or check the components; if necessary, replace