00191494-01 - 第99页

Short Reference SIPLACE 80 S-15/F3/G Error Messages 03/99 Issue Software Version SR.010.x x 97 1019 yk-axis: T arget position not reached CAUSE ● Machine data not correct; me chanism is jamming; drive motor, tachometer ,…

100%1 / 124
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
96
1006 Z-axis; GU2: Bero at top does not react
CAUSE
Z2-axis is not positioned high enough; Bero defective; Z2-axis is jamming
motor, controller, servo-amplifier defective.
REMEDY
Check the components just mentioned.
1007 Z-axis; GU3: Bero at top does not react
CAUSE
Z3-axis is not positioned high enough; Bero defective; Z3-axis is jamming
motor, controller, servo-amplifier defective.
REMEDY
Check the components just mentioned.
1010 Z-axis; GU1: cannot be moved any further upwards
CAUSE
When the start button is pressed the Z1-axis is below the minimum position
REMEDY
The servo-amplifier should be checked; slide the Z1-axis upwards by hand
1011 Z-axis; GU2: cannot be moved any further upwards
CAUSE
When the start button is pressed the Z2-axis is below the minimum position
REMEDY
The servo-amplifier should be checked; slide the Z2-axis upwards by hand
1012 Z-axis; GU3: cannot be moved any further upwards
CAUSE
When the start button is pressed the Z3-axis is below the minimum position
REMEDY
The servo-amplifier should be checked; slide the Z3-axis upwards by hand
1018 xk-axis: Target position not reached
CAUSE
Machine data not correct; mechanism is jamming;
drive motor, tachometer, incremental encoder, servo-amplifier defective; calibration of the axis
incorrect.
REMEDY
Check machine data; check the mechanism; check the axis calibration
or check the components; if necessary, replace
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
97
1019 yk-axis: Target position not reached
CAUSE
Machine data not correct; mechanism is jamming;
drive motor, tachometer, incremental encoder, servo-amplifier defective; calibration of the axis
incorrect.
REMEDY
Check machine data; check the mechanism; check the axis calibration
or check the components; if necessary, replace
1020 Z-axis; GU1: Target position not reached
CAUSE
Machine data not correct; mechanism is jamming;
drive motor, tachometer, incremental encoder, servo-amplifier defective; calibration of the axis
incorrect. Cam is in incorrect position with respect to zero pulse
REMEDY
Check machine data; check the mechanism; check the axis calibration
or check the components; if necessary, replace, fit cam in correct rotational position; redetermine
zero point correction
1021 Z-axis; GU2: Target position not reached
CAUSE
Machine data not correct; mechanism is jamming;
drive motor, tachometer, incremental encoder, servo-amplifier defective; calibration of the axis
incorrect.
Cam is in incorrect position with respect to zero pulse
REMEDY
Check machine data; check the mechanism; check the axis calibration
or check the components; if necessary, replace, fit cam in correct rotational position; redetermine
zero point correction
1022 Z-axis; GU3: Target position not reached
CAUSE
Machine data not correct; mechanism is jamming;
drive motor, tachometer, incremental encoder, servo-amplifier defective; calibration of the axis
incorrect.
Cam is in incorrect position with respect to zero pulse
REMEDY
Check machine data; check the mechanism; check the axis calibration
or check the components; if necessary, replace, fit cam in correct rotational position; redetermine
zero point correction
1023 xk-axis: deactivated
CAUSE
Axis has been deactivated at the axis board (servo)
REMEDY
Switch on the axis at the axis card
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
98
1024 yk-axis: deactivated
CAUSE
Axis has been deactivated at the axis board (servo)
REMEDY
Switch on the axis at the axis card
1025 Z-axis; GU1: deactivated
CAUSE
Axis has been deactivated at the axis board (servo)
REMEDY
Switch on the axis at the axis card
1026 Z-axis; GU2: deactivated
CAUSE
Axis has been deactivated at the axis board (servo)
REMEDY
Switch on the axis at the axis card
1027 Z-axis; GU3: deactivated
CAUSE
Axis has been deactivated at the axis board (servo)
REMEDY
Switch on the axis at the axis card
1028 xk-axis: Position control does not work
CAUSE
The position control of the axis is not working properly; machine data are not correct
REMEDY
Switch off the machine (reset), check axis for stiffness of running; check the machine data
1029 yk-axis: Position control does not work
CAUSE
The position control of the axis is not working properly; machine data are not correct
REMEDY
Switch off the machine (reset), check axis for stiffness of running; check the machine data
1030 Z-axis; GU1: Position control does not work
CAUSE
The position control of the axis is not working properly; machine data are not correct
REMEDY
Switch off the machine (reset), check axis for stiffness of running; check the machine data