80S-20贴片机 - 第127页

SIPLACE 80S -20/F4/F4-6/F5 Service Manual 5 Gantries Edition 09/99 5.5 Replacing the Drive Motor of the Y A xis 5 - 19 Fig. 5.5.1 Y -motor unit

100%1 / 483
5 Gantries SIPLACE 80S-20/F4/F4-6/F5 Service Manual
5.5 Replacing the Drive Motor of the Y Axis Edition 09/99
5 - 18
5.5 Replacing the Drive Motor of the YAxis
5.5.1 Spare Parts, Auxiliary Materials and Equipment
1 motor for the y axis, complete, from item no. 00318603-01
Belt tension measuring device, from item no. 00326015-01
5.5.2 Removal
NOTE
You should comply with the safety instructions in Section 1.
Move the gantry out of the working area to prevent any damage to it.
Disconnect the components table cable and remove the components table.
Remove the empty tape cutter by undoing the four mounting screws and disconnect the connection cable.
You will only need to do this with SIPLACE 80S-20 machines.
NOTE
While you are carrying out this work be careful not to damage or dirty the scale and the reading head.
Clean soiled scales as described in the maintenance instructions.
Remove the stop support together with the stop (applies to F
4
, F
4
-6 and F
5
only).
Remove the lateral sliding plate holder together with the sliding plate.
Remove the components table support.
Loosen the y-belt at the tension rollers using the hexagon socket screw key, size 8.
Undo the two M6 mounting screws and remove the motor.
With gantry 1, disconnect the electrical connections of the motor unit. In the case of gantry 2 the electrical
connections are located behind the main switch.
NOTE
The motor is supplied as a complete unit consisting of the motor itself, the tachometer and motor pinion and
for this reason should also be replaced as a complete unit.
SIPLACE 80S-20/F4/F4-6/F5 Service Manual 5 Gantries
Edition 09/99 5.5 Replacing the Drive Motor of the Y Axis
5 - 19
Fig. 5.5.1 Y-motor unit
5 Gantries SIPLACE 80S-20/F4/F4-6/F5 Service Manual
5.5 Replacing the Drive Motor of the Y Axis Edition 09/99
5 - 20
5.5.3 Installation
Fit the new motor using the mounting screws.
Restore the motor’s electrical connections (depending on the gantry)
NOTE
Route your cables with care.
Tension the cut toothed belt as described in Table 5.5 - 1.
Fit the components table support and the sliding plate holder.
Replace the empty tape cutter and restore all electrical and pneumatic connections.
Carry out a complete adjustment of the y axis (see adjustment instructions).
Key to Fig. 5.5.1
.
Length of the toothed belt 2540 mm
Measurement position on the toothed belt
600 mm from the center of the motor pinion to the center of the ten-
sioning roller on the motor side (see item A in Fig. 5.5.1)
Frequency of the new toothed belt 46 Hz ± 1 Hz
Frequency of the toothed belt once run in
(t
5 hours
)
46 Hz ± 1 Hz
Table 5.5 - 1 Required adjustment of the cut toothed belt for the y axis
1 Stop (remove only in F
4
, F
4
-6 or
F
5
machines
2 Sliding plate and sliding plate holder
3 Y motor 4 Y-axis toothed belt
5 Tension rollers 6 X gantry
7 Y-axis deflection roller A Adjustment for the toothed belt tension: 600 mm distance