7 Components Table SIPLACE 80 S-20/F4 Service Manual 7.1 Overview Edition 03/97 7 - 8 Fig. 7.1.3 Empty tape cutting unit : mounting in t he machine base, structure and connections

100%1 / 483
SIPLACE 80 S-20/F4 Service Manual 7 Components Table
Edition 03/97 7.1 Overview
7 - 7
7.1.3 Empty Tape Cutting Device
7.1.3.1 Electrical / Pneumatic Systems
The voltage supply (30 VDC ) and the control of the empty tape cutting unit is handled by the correspond-
ing communications unit: plug X3ak on the tape cutting unit "Tape cutter interface" cable Y543-W1
plug X37 in the machine base "Components table interface" cable Y559-W1 communications unit.
In the event of overload the direct current geared motor (30 VDC) will be switched out by the PTC ther-
mistor (communications unit). Once the cause has been corrected (stiffness) and the resistor cooled down
the cutting cycle can be restarted.
The (double-acting) compressed air cylinder is connected directly to the 5.6 bar compressed air branch (=
fixed and preset operating pressure) at the compressed air unit (see Fig. 7.6.6).
Upon application of compressed air (actuation of the 3/2-way solenoid valve) the plunger retracts,
after a further actuation of the solenoid valve (= zero-pressure state) the plunger is reset by the two
tension springs on the left and right of the tape cutting unit. This causes the pressure rod to swing in
(see Fig. 7.6.7).
Damping at the end positions is handled by the tube restrictor inserts in the supply and exhaust air
connections.
Motor (cutting stroke) and solenoid valve (swing movement) are operated in parallel.
When the machine is switched off the pressure rod is kept in the swung-in position by the two tension
springs on the left and right of the tape cutting unit (see Fig. 7.1.3).
7.1.3.2 Functional Sequence
After the machine has been switched on (compressed air is on, d.c. motor is not activated) the pressure
rod swings away from the empty tape channel (see Fig. 7.1.3) during the cycling of the feeder module
which follows, the empty tape can slip downwards in the empty tape channel .
After (at the present time) every fourth belt cycle the motor of the empty tape cutting unit is activated and at
the same time the solenoid valve at the compressed air cylinder actuated.
The compressed air cylinder goes to zero pressure the two tension springs swing in the pressure rod
(see Fig. 7.6.9) the carriage with cutter wheel travels to the right (= cutting stroke) the empty tape is
cut away.
When the end of cutting stroke (656 mm) is reached the carriage triggers the right-hand limit switch the
direction of rotation of the motor is changed the carriage returns to its starting position and triggers the
left-hand limit switch (= parking position ) the motor current is switched off the solenoid valve
switches and the compressed air cylinder retracts the pressure rod (angle section) swings away and
releases the empty tape which drops into the waste tape container.
The sequence repeats itself as described above (from the second paragraph).
7 Components Table SIPLACE 80 S-20/F4 Service Manual
7.1 Overview Edition 03/97
7 - 8
Fig. 7.1.3 Empty tape cutting unit : mounting in the machine base, structure and connections
SIPLACE 80 S-20/F4 Service Manual 7 Components Table
Edition 03/97 7.1 Overview
7 - 9
7.1.4 Components Table Compressed Air Supply Unit (Option)
Fig. 7.1.4 Components table compressed air supply , top view
When compressed air feeder modules (= feeder modules which operate using compressed air) are to be used
the optional "components table compressed air supply unit" (see diagram above) together with the "compo-
nents table pneumatic system" (see Fig. 7.1.4) is installed in the SIPLACE 80 S machine.
This "components table compressed air supply unit" (= compressed air distributor strip) is fitted in a
defined position on the longer side of the changeover components table (see Fig. 7.1.2) by means of 3
centering pins and fastened down to the components table with 3 socket-head cap screws M8.
Each compressed air feeder module after installation at the components table is attached to the com-
pressed air distributor strip by means of a clip fastener. When the module is used the corresponding
plunger is pressed downwards into the compressed air distributor strip which assures continuous availabil-
ity of compressed air at the module.
Connection to the power supply is at the corresponding socket on the connections panel (communications
unit).
Actuation of the solenoid valves in the feeder module operates the compressed air branch in the module
and the components are conveyed onwards, separated into singles and brought into the pick-up position.