80S-20贴片机 - 第246页

7 Components Table SIPLACE 80 S-20/F4 Service Manual 7.6 Empty Tape Cutting Unit and Empty Tape Channel Edition 03/97 7 - 44 7.6.12 Swivel Mechanism – If the pr essure rod is not p ressed strongl y enough agains t the sp…

100%1 / 483
SIPLACE 80 S-20/F4 Service Manual 7 Components Table
Edition 03/97 7.6 Empty Tape Cutting Unit and Empty Tape Channel
7 - 43
Fig. 7.6.5 Replacing and tensioning the endless toothed belt
Key to Fig. 7.6.5
1 Clamping connector
2 Drive motor
3 Cutter wheel carriage
4 Deflection pulley
5 Endless toothed belt
A Insert endless toothed belt
B Check, whether the toothing of the clamping connector engages in the toothing of the endless toothed belt
C Screw on clamping connector without squashing the toothed belt
D Measure tension of toothed belt in the center of the belt, setpoint value: 30-35 Hz
E To measure belt tension, move up cutter wheel carriage to the left stop
F Correct tension of toothed belt using the movable deflection pulley, if necessary
,,
4
F
E
3
5
2
1
D
A B C
7 Components Table SIPLACE 80 S-20/F4 Service Manual
7.6 Empty Tape Cutting Unit and Empty Tape Channel Edition 03/97
7 - 44
7.6.12 Swivel Mechanism
If the pressure rod is not pressed strongly enough against the spring bows or the empty tape during the
cutting process (see Fig. 7.6.8), the tapes may slip over one another during cutting (tape jam, poor cuts).
If the pressure rod does not swing out far enough when the tape cycles on, the tapes may not slide down
the empty tape channel which will also lead to a tape jam.
A fault in the swivel movement can indicate a fault in the 5.6 bar compressed air branch, in the solenoid valve,
in the compressed air cylinder, or incorrect adjustment of the restrictor valves or fatigued tension springs.
Detailed information on the electrical and pneumatic systems and on the functional sequence will be found
under "Overview" in Section 7.1.3 ’Empty Tape Cutting Device’.
7.6.12.1 Checking the Swivel Movement
Please read and observe the DANGER notice concerning working with the SITEST program (danger of
physical injury) in Section 7.6.2, page 7 - 30.
Select "Abort placement" and load the SITEST program.
If necessary, have on hand the detailed functional sequence described in Section 7.1.3 ’Empty Tape Cut-
ting Device’.
Select "Component table" "Single functions" "Tape cutting unit".
At the same time check by eye the empty tapes and the swivel movement of the pressure rod.
If the pressure rod does not swing far enough in or out, check the compressed air branch as described
below.
If the pressure rod swings in too slowly or bounces as it swings in or out, adjust the supply or exhaust
air restrictor valve (see "Concluding work").
7.6.12.2 Checking the Compressed Air Branch
Remove the compressed air unit cover from the machine base (undo 2 special socket-head cap screws
M3).
Check the threaded hose connections at the solenoid valve of the tape cutting unit (see Fig. 7.6.7) and at
the compressed air unit (see Fig. 7.6.6) for leaks.
If these screwed connections are okay:
DANGER QQQ
Switch off the machine at the main switch and disconnect it from the main power supply and in addition
switch off the compressed air supply line at the shut-off valve on the compressed air unit (see Fig. 7.6.6).
Check the compressed air hose between the compressed air unit and the solenoid valve:
If the compressed air hose pinched, replace it. Replace all of the cable lacings.
Open the shut-off valve in the compressed air supply line and switch the machine on at the main
switch.
SIPLACE 80 S-20/F4 Service Manual 7 Components Table
Edition 03/97 7.6 Empty Tape Cutting Unit and Empty Tape Channel
7 - 45
Check the figures shown by the pressure gauges and refit the cover over the compressed air unit
at the machine base (2 special socket-head cap screws M3).
If there is still a fault, the compressed air cylinder or the solenoid valve could be defective. Continue
work with the next section.
NOTE:
The + 30 VDC electric circuit and the activation of the solenoid valve were already checked earlier in Sec-
tion 7.6.2.1.
Fig. 7.6.6 Compressed air connection of the tape cutting units and electrical connection of the solenoid valve (cable Y638-W1/W2)